OPERATION - MAINTENANCE - TECHNICAL DATA
TSC OPERATION
As soon as the TSC is powered, the Power ON and Power OFF LEDs will switch on for two seconds.
Afterwards, if the mushroom push-button is not pressed, the Power ON LED will start fl ashing slowly indicating
that the system is on hold (TCD and TMS disabled), whereas the Power OFF LED will be off.
If a TCD command connected to the system is enabled, the Power ON LED will switch on steady, showing that
the TCD and TMS are enabled.
In case the mushroom push-button is pressed, the Power OFF LED will switch on and the TCD controls present
and the TMS will be disabled (Power ON LED off).
In order to release the mushroom push-button, the red knot must be turned clockwise.
WARNING: press the mushroom push-button switch only in case of emergency. As soon as the
emergency situation is solved, unlock the mushroom push-button switch.
MAINTENANCE
The TSC needs no particular maintenance. To ensure optimum performance from the command, once a year
check the cables and the electrical connections.
Clean the TSC with a soft cloth dampened with water. Do not use chemical or abrasive products to clean the
command.
TECHNICAL DATA
MODEL
INPUT CHARACTERISTICS
(1)
Supply voltage
(2)
Current absorption
Maximum current absorption
AMBIENT CHARACTERISTICS
Operating temperature
(3)
Protection rating
GENERAL
Dimensions including frame
Weight
EMC standard
(1) With supply voltage less than 8 Vdc the system can reset.
(2) Typical value.
(3) Excluding the back of the TSC (IP20).
®
QUICK
RESERVES THE RIGHT TO MODIFY THE TECHNICAL CHARACTERISTICS OF THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE.
TSC MAIN SWITCH COMMAND - REV001B
LED
POWER OFF
(2)
(L x L)
TSC
from 8 to 31 Vdc
10 mA
40 mA
from -20 to +70 °C
IP 65
78 mm x 78 mm
110 g
EN 60945 - FCC TITLE 47 PART 15 SUBPART B CLASSE B
LED
POWER ON
MUSHROOM PUSH-BUTTON SWITCH
GB
11