Fujitsu AirStage ASYA18GACH Manual De Instalación página 14

Ocultar thumbs Ver también para AirStage ASYA18GACH:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
00
Default
Heat air
01 Adjust (1)
tempera-
31
02 Adjust (2)
ture trigger
03 Adjust (3)
00
Enable
Auto restart
40
01
Disable
00 Super low
Follow the
Cool Air
43
setting
Prevention
01
on the
remote
controller
00 Start/Stop
External
46
Emergen-
control
01
cy stop
Forced
02
Stop
00
All
Display
Error report
47
only on
target
01
central
remote
controller
Follow the
Fan set-
setting
ting when
00
on the
cooling
49
remote
thermostat
controller
OFF
01
Stop
7.4.1. Button name and function
OPERATION indicator lamp (Green)
TIMER indicator lamp (Orange)
FILTER indicator lamp (Red)
En-13
9373370147-01_IM.indb 13
9373370147-01_IM.indb 13
Adjust the heat air trigger
temperature. To lower the trigger tem-
perature by 6 degrees C, use setting
01. To lower the trigger temperature
by 4 degrees C, use setting 02. To
raise the trigger temperature, use set-
ting 03.
Enable or disable automatic system
restart after a power outage.
* Auto restart is an emergency func-
tion such as for power failure etc.
Do not start and stop the indoor unit
by this function in normal operation.
Be sure to operate by the control
unit, converter or external input
device.
Restrain the cold airfl ow with making
the airfl ow lower when starting heat-
ing operation. To correspond to the
ventilation, set to 01.
Allow an external controller to start
or stop the system, or to perform an
emergency stop.
* If an emergency stop is performed
from an external controller, all refrig-
erant systems will be disabled.
* If forced stop is set, indoor unit stops
by the input to the external input ter-
minals, and Start/Stop by a remote
controller is restricted.
Change the target for reporting er-
rors. Errors can either be reported in
all locations, or only on the central
remote controller.
When set to 01, the fan stops when
the thermostat is OFF in cooling
operation. Connection of the wired re-
mote controller (2-wire type or 3-wire
type) and switching its thermistor are
necessary.
7.4.2. Checking the function settings
Press and hold the "MANUAL AUTO" button on the indoor unit for 3 seconds to check
the function settings. It is necessary to disconnect the power in order to return to normal
operation mode.
(1) Indoor unit and refrigerant address indication
Indication pattern
Indicator name
Indoor unit address
OPERATION indicator lamp (Green)
ON
TIMER indicator lamp (Orange)
Address: tens place (0.5s ON/0.5s OFF)
FILTER indicator lamp (Red)
Address: ones place (0.5s ON/0.5s OFF)
• Indoor unit address example
(Example) ADDRESS : 24
1 cycle 12 sec
OPERATION
ON
indicator lamp
(Green)
OFF
ON
TIMER
indicator lamp
0.5s 0.5s 0.5s 0.5s
(Orange)
OFF
ON
FILTER indica-
0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s
tor lamp
OFF
(Red)
• Refrigerant address example
(Example) ADDRESS : 30
1 cycle 12 sec
OPERATION
ON
indicator lamp
1.0s
1.0s
1.0s
(Green)
OFF
TIMER
ON
indicator lamp
0.5s 0.5s 0.5s 0.5s 0.5s 0.5s
(Orange)
OFF
ON
FILTER indica-
tor lamp
OFF
OFF
(Red)
• Setting details
Function number
Item
01
Indoor unit address
02
Refrigeration address
For use with a remote controller, set all rotary switches to 0, and refer to "7.1. Setting the
address" for details.
All switches are set to 0 at the factory.
(2) Others
Indication pattern
Indicator Name
OPERATION indicator lamp (Green)
Function number; tens place (0.5s ON/0.5s OFF)
TIMER indicator lamp (Orange)
Function number; ones place (0.5s ON/0.5s OFF)
FILTER indicator lamp (Red)
Setting number: (0 to 9) (0.5s ON/0.5s OFF)
(Example) Function : 31, Setting number : 2
1 cycle 12 sec
OPERATION
ON
indicator lamp
0.5s
0.5s
0.5s
0.5s 0.5s 0.5s
(Green)
OFF
TIMER
ON
indicator lamp
0.5s 0.5s
(Orange)
OFF
ON
FILTER indica-
tor lamp
0.5s
0.5s
0.5s
0.5s
(Red)
OFF
Indication pattern
Refrigerant address
Flash (1.0s ON/1.0s OFF)
ON
10 sec
8 sec
1.0s
1.0s
1.0s
1.0s
9 sec
Setting number
00 to 63
00 to 99
Indication pattern
9 sec
11 sec
10 sec