Installation
Attach Wire Connectors to Wires
1. Remove the screws (4) securing the switch plate to the lock box housing.
2. Slide the plastic boot on to the wire.
3. Strip 1/2" (12.7 mm) of insulation from the end of the wire.
4. Insert exposed wire into the wire connector and crimp the tangs down to
secure the wire.
5. Slide the plastic boot over the connector.
6. Tug on the wire to ensure it is secure in the connector.
7. Insert the wires into the lock box through the top grommets.
See Install the Control Station and Wiring below.
Wire
Connector
Install the Control Station and Wiring (120 Vac)
1. Disconnect ALL power before proceeding.
2. Connect wires to the control station as shown and reattach the switch plate.
3. Mount the control station to the wall using appropriate hardware.
4. Run power wires and connect power.
Back of
Control
Station
Control Station
Terminals
N/O
COM
N/O
Install the Control Station and Wiring (230 Vac)
1. Disconnect ALL power before proceeding.
2. Connect wires to the control station as shown and reattach the switch plate.
3. Mount the control station to the wall using appropriate hardware.
4. Run power wires and connect power.
Back of
Control
Station
Control Station
Terminals
N/O
COM
N/O
Plastic Boot
1/2"
(12.7 mm)
1
White
From
Red
Motor
Black
To Power
Red
3
L
Source
Blue
N
(120V/60Hz)
Blue
1
Brown
From
Motor
Black
Red
3
L
To Power Source
Blue
(230V/50Hz)
N
Wire
8
2
2