STAINLESS STEEL SINK: Same as porcelain sinks.
4. DRAIN CLAMP CONNECTION
Use black plastic drain clamp provided in the installation kit, which fits most
standard drain sizes of 1-1/4". Install drain clamp above the P-trap as close to
the bottom of the basin as possible and drill a ¼" hole where the plastic fitting is
to be installed. Install the drain connection fitting.
NOTE: IF USING DRAIN LINE ADAPTOR (DLA) FOLLOW INSTRUCTIONS
ENCLOSED WITH DLA KIT.
5. SYSTEM HOOK UP
AIR GAP FAUCET: After the hole for a faucet has been drilled, and the system is
in place, disassembles the bottom portion of the faucet. Slip ¼" black line through
the faucet hole in the sink and connect onto small barbed fitting of faucet. Slip
3/8" tubing on the large barbed fitting. Put the faucet into the hole of the sink and
reassemble the faucet from underneath the sink.
STANDARD FAUCET: Disassemble the bottom portion of a faucet, put into hole
of sink and reassemble faucet from underneath the sink.
¼" RED LINE: Connect from system to feed adaptor. (Use an insert and sleeve
provided in installation kit.)
3/8" BLUE LINE: Install the 7/16" compression x 3/8" Quick-connect fitting onto
the faucet shank and connect the blue line to the adaptor.
¼" YELLOW LINE: Connect from system to holding reservoir. (Use an insert
provided in installation kit).
¼" BLACK LINE: (Standard Faucets): Connect to drain clamp fitting using ¼"
insert provided in installation kit. (Air Gap Faucets): Connect the ¼" black line to
the small barb fitting on the faucet, slip 3/8" black line on larger barb fitting on
faucet. Connect opposing end of tubing to drain clamp fitting using insert
provided in kit.
SYSTEM START UP: Slowly open angle valve (on feed adapter) allowing raw
water to enter system. Leave faucet open until water is running, then close RO
faucet.
CHECK FOR LEAKS: Move ball valve lever on storage tank to open (UP)
position.
CHECK FOR LEAKS: Allow system to run while cleaning up tools. Check all
connections, including those inside the unit for leaks. Before use, allow tank to fill
(6 hours minimum), then drain completely from the RO faucet to flush out
sanitizer and carbon fines. Allow system to refill.