Station type
Secondary
station
address
Door opener
Interruption
Camera
lights
DOOR OPENING TIME The position of the rotary switch (DOOR TIME) determines the activation time of
the door lock.
Pos. 0 = 1 s
Pos. 1 = 10 s
Pos. 4 = 40 s
Pos. 5 = 50 s
Pos. 8 = 80 s
Pos. 9 = 90 s
GUARANTEED CONVERSATION TIME The position of the rotary switch (CONV TIME) determines a
guaranteed conversation time, i.e. extends the busy time from the answer onwards.
The busy time is equal to the reply time (max. 0s) added to the guaranteed conversation time.
Pos. 0 = 1 s
Pos. 1 = 10 s
Pos. 4 = 40 s
Pos. 5 = 50 s
Pos. 9 = NOT ALLOWED
§
The guaranteed conversation time must be programmed in the same way for all system call stations.
DS1083-048
AUX
ON
DIP
Main
1
2
3
4
5
ON
DIP
Secondary 0
1
2
3
4
5
ON
DIP
Door opener
free
1
2
3
4
5
ON
DIP
On
1
2
3
4
5
Camera
ON
DIP
lights
off
1
2
3
4
5
Pos. = 0 s
Pos. 3 = 30 s
Pos. = 0 s
Pos. 7 = 70 s
Pos. = 0 s
Pos. = 0 s
ON
DIP
Secondary
1
2
3
4
5
ON
DIP
Secondary 1
1
2
3
4
5
ON
DIP
Door opener
privacy
1
2
3
4
5
ON
DIP
Off
1
2
3
4
5
Camera
ON
DIP
lights
on
1
2
3
4
5
Pos. 3 = 30 s
Pos. 7 e 8 = 70 s
15