Campbell Hausfeld PW320200 Manual De Instrucciones página 15

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1.
In a well ventilated outdoor area add fresh, high quality, unleaded gasoline with a pump octane
rating of 86 or higher. Do not overfill. Wipe up spilled fuel before starting the engine. Refer to Engine
Owner's Manual for correct procedure.
Use of fuels with greater than 10% ethanol are not approved for
use in this product per EPA regulations and will damage the unit
and void the warranty.
2.
Check engine oil level. Refer to Engine Owner's Manual for correct procedure.
3.
Connect the water hose to the water source. Turn the water source on to remove all air from the hose.
When a steady stream of water is present, turn the water source off.
4.
Verify the filter screen (M) is in water inlet of pump. NOTE: Convex side faces out.
M
Figure 20
5.
Connect water source (N) to pump inlet (J). NOTE: Water source must provide a minimum of 5 gallons
per minute at 20 PSI.
6.
Connect high pressure hose (C) to pump outlet (I).
To reduce the possibility of contamination always protect against backflow when connected to
a potable water system.
7.
Choose the correct nozzle for the job to be performed. See How To Use spray Wand instructions in this
section. NOTE: If applying a chemical or cleaning solution, see How To Apply Chemicals/Cleaning
Solvents instructions in this section.
8.
Turn water source on.
Risk of property damage. Failure to do so could cause damage to the pump.
9.
Remove all air from the pump and high pressure hose by depressing trigger until a steady stream of
water is present.
10. Start engine. See Engine Owner's Manual for correct procedure.
Risk of unsafe operation. If engine does not start after two pulls, squeeze trigger of gun to
relieve pump pressure. Pull starter cord slowly until resistance is felt. Then pull cord rapidly to
avoid kickback and prevent hand or arm injury.
NOTE: If the oil level in the engine is low, the engine will not start. If the engine does not start, check the oil
level and add oil as needed.
11. Depress trigger on gun to start water flow.
Risk of unsafe operation. Stand on a stable surface and grip gun/spray wand firmly with both
hands. Expect the gun to kick when triggered.
12. Release trigger to stop water flow.
Do not allow the unit to run for more than two minutes without the gun trigger being pulled.
This could cause overheating and damage to the pump. When the temperature inside the pump
rises too high, the thermal relief valve will open and release a spray of water from the pump to lower the internal
temperature. The valve will then close.
J
I
N
C
13
Tabla de contenido
loading

Tabla de contenido