6 Putting into operation
6.2 Equipping the hose assembly
1
Connection module
2
EMERGENCY STOP cable
3
Control line
Fig. 5
Equipping the hose assembly
6.3 Mounting the machine side connection
EN - 10
5 Tighten the hexagonal head screws using the Allen key (7) .
6 Insert the Neck Liner (5) on the connection side through the connecting
module (6) into the torch neck (4) .
1
8
7
4
Air-blast hose
5
Central plug
6
Connection nut
NOTE
• Select the proper wire type and the related wire guide.
• For cutting the wire size and for correct mounting, please observe the
following chapters:
See 9 Maintenance and cleaning on page EN-13
• Guide spiral liners = for steel and stainless steels
• PA liners = for aluminum, copper, nickel and stainless steels
1 Lay out the hose assembly (7) straight and attach it to the connection
module (1) on the torch neck side.
2 Slide the ready-to-use wire guide from the central plug (5) up to the stop in
the changeable body and screw it down by means of the connection nut
(6) .
If required, connect the EMERGENCY STOP cable (2) of the CAT robot mount
(8) to the hose assembly (7) .
See 6.4 Connect the control line on page EN-11
See Fig. 5 Equipping the hose assembly on page EN-10
2
6
7
8
ABIROB
3
4
5
Hose assembly
CAT robot mount
®
A