DOOR UNIT TYPE
This parameter is used to set the door audio and audio-video door unit as primary or secondary. All the users in
the system may be called from the main door unit. A secondary door unit may only call the users of the riser to
which it belongs. Users who receive the call can identify the source of the call by the tone.
If the value "SECONDARY" is selected, new parameters are displayed on the web page and are
described in chapter DOOR UNIT TYPE: SECONDARY.
MAIN DOOR UNIT ADDRESS
Set the identification number (ID) of the door unit to a value from "0" to "3". No two main units can have the same
ID.
DOOR OPENER TYPE
This is used to manage lock door opener mode; possible options are "FREE" or "SECRET".
In "SECRET" mode, the electric lock may only be activated by pressing the door opening button on the calling
station when an audio conversation has been established or when after having received a call or auto-on function
either a video connection has been established.
In "FREE" mode, instead, the apartment station door opener button will only open the door unit electrical lock only
if the door unit is configured as main or the user belongs to the same door unit column. This column is defined by
the secondary door unit ID setting. This function is typically used for secondary stations.
The above applies to the vehicle and pedestrian gate electrical lock (gate).
AUTO-ON / INTERRUPTIBLE INTERCOM
When an auto-on or intercom conversation is in progress, the concerned column or the entire system will be busy
but can be interrupted (according to the configuration of this parameter) by a call from the door unit (if "YES" is
selected).
The parameter must be programmed in the same manner on all calling stations in the system.
GUARANTEED CONVERSATION TIME
The position of the parameter determines a guaranteed conversation time, i.e. extends the busy time from the
answer onwards. The busy time is equal to the reply time (60 s) added to the guaranteed conversation time.
The parameter must be programmed in the same manner on all calling stations in the system.
PEDESTRIAN DOOR OPENING TIME
The value of the parameter determines the pedestrian electric lock holding time (max. 90 s).
CAMERA LIGHT (#)
This parameter can be used to configure the camera LEDs to light up during the call and the auto-on function
(with audio in progress). If the value is "ENABLED", the camera LEDs light up in the steps indicated above; if the
value is "DISABLED", the camera LEDs will stay off.
AUTOMATIC DOOR OPENER
The automatic door opener function can be used to automatically open the door when you make a call from
outside to the apartment. If the value is "ENABLED" the function is active, if the value is "DISABLED" the function
is not active.
The service must also be enabled on the indoor set.
USE DOOR SENSOR FOR...
The parameter allows to enable the input (15) for one of the following two functions:
"DOOR STATUS": this is used to detect the opening of the entrance door (by using an additional Normally
Closed magnetic sensor);
"LETTERBOX" (block): this can be used to signal the presence of mail in the letterbox (future
implementation).
CALL TONE IN PROGRESS ON/OFF
The parameter is used to enable or disable the acoustic signal on the speaker of the door unit during a call
(according to the telephone standard 1 s ON and 4 s OFF).