_900_serie.book Seite 44 Mittwoch, 22. März 2006 4:28 16
Servicing and cleaning
Note
The battery chargers 915-012TB, 925-012TC and 915-024TC
have a charging output for the starter battery. The output voltage
is between 13.2 V (26.4 V) and 13.8 V (27.6 V) and can recharge
the starter battery with a current of 1 A or keep it at a high
capacity level.
6.3
Functional check
The charging process of the batteries can be checked via an LED at the front
of the unit:
Note
The check of the unit can occur also with the optionally available
remote control. The LEDs on the remote control indicate the
colours and the appropriate charging phases.
LED
red
yellow
green
7
Servicing and cleaning
Caution!
Never use sharp or hard detergents as they can damage the unit.
➤ Clean the outside of the IU0U automatic charger from time to time with a
damp cloth.
44
Charging phase
I phase
U0 phase
U phase
IU0U automatic charger
Charging status of the battery
between 10 % and 50 %
between 10 % and 50 %
over 90 %