Dip switch
AUTOMATIC
1
CLOSING
2
2 / 4 STROKE
OPENING
3
PHOTOCELLS
OPERATION
4
NO REVERSE
DECELE-
5
RATION
PRE-
6
FLASHING
PHOTOCELL
7
TEST
8
2
RADIO CH
nd
OPERATION
9
OPENING
10
DIRECTION
SETUP
Clock function:
A timer can be connected to the open-close pushbutton in order to keep the gate open at certain
times during the day, after which it reverts to automatic closing.
433.92 MHz BUILT-IN RADIO RECEIVER
The radio receiver can learn up to a maximum of 8 dip-switches (TXD2, TXD4, BUG2, BUG4,
K-SLIM, K-SLIM-C, T-4, T-4C) or rolling codes (BUG2R, BUG4R, K-SLIMRP, T-4RP) which can
be set on the two channels as required.
The first channel directly commands the control board for opening the automatic device; the
second channel commands a relay for a N.O. no-voltage output contact (terminals 18 and 19,
max. 24 Vac, 1 A).
The learning mode (dip-switch or rolling code) is determined by the first radio control device and
remains unchanged until all the codes have been cancelled.
after opening, the gate automatically closes when the delay set on
On
the T.C.A. trimmer expires.
Off
automatic closing disabled.
with automatic closing enabled, a sequence of open/close com-
On
mands causes the gate to OPENCLOSE-OPEN-CLOSE etc (see
also dip switch 4).
in the same conditions, the same command sequence causes the
Off
gate to OPEN-STOP-CLOSESTOP-OPEN-STOP (step-by-step).
during opening, the photocell cuts in to stop the gate until the ob-
On
stacle is removed.
Off
during opening, the photocell does not cut in.
On
the direction of movement is only changed during closing.
the open-close pushbutton reverses the direction of movement of
Off
the gate even while it is opening.
On
the deceleration function is off;
the deceleration function is on and can be adjusted by means of
Off
the RALL trimmer;
On
the pre-flashing function enabled.
Off
the pre-flashing function disabled.
On
the "photocell test" function is enabled;
the "photocell test" function is disabled. N.B.: to be used when the
Off
photocells are not used;
monostable function of the CH2 control relay (terminals 18 and
On
19) enabled;
bistable (or STEP-BY-STEP) function of the CH2 control relay (ter-
Off
minals 18 and 19) enabled;
with dip-switch 8 ON (monostable function), the N.O. contact re-
On
mains closed for 180 secs. (fixed invariable delay for the timed
control of the lights);
with dip-switch 8 ON (monostable function), the N.O. contact re-
Off
mains closed for 2 secs. (fixed invariable delay for commanding a
second automatic system).
On
right-hand leaf opening function;
Off
left-hand leaf opening function;
K570M
15