Troubleshooting Guide - 3M Aqua-Pure AP Easy Serie Manual De Instalación Y Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

PORCELAIN/ENAMEL/CERAMIC SINKS
To reduce the risk aof eye injury while drilling counter-tops for faucet installation:
• Safety glasses MUST be worn during the sink hold drilling operations.
Drilling Hole through Porcelain/Enamel/Ceramic Sinks with Sheet Metal or Case Iron Base
Recommended Tools:
Variable Speed Drill
Porcelain Cutter Tool Set (9/16" Size)
Plumber's Putty
Note: It is important to understand this procedure.
1. The glassy layer of porcelain/enamel/ceramic must be scored through to the metal base, creating a disk.
2. This disk must be removed while protecting the surrounding decorative coating against chipping or fracturing.
3. The base metal must be drilled through to complete the hole.
Procedure:
1. Mark center for 9/16" hole.
2. Form a dam of shallow putty around hole location and fill with enough water to lubricate carbide drill bit.
3. Carefully drill pilot hole through porcelain/enamel/ceramic and base metal using a carbide pilot drill. Always operate
drill with light pressure at slow speed (300 - 400 rpm).
4. Drill porcelain/enamel/ceramic using special 9/16" cutting tool, making certain a complete ring has been cut through
to the sink's metal base.
5. Change to metal cutting drill bit and drill out the center of the ring, making sure not to contact other rim of decorative
coating. Cut through metal sink base.
FILTER CARTRIDGE REPLACEMENT INSTRUCTIONS
To reduce the risk associated with property damage due to water leakage:
• The disposable filter cartridge must be replaced every twelve (12) months or at the specified service cycle.
1. Grasp cartridge and turn to the left (counterclockwise) until cartridge comes to a complete stop. Gently pull down-
ward to remove.
2. Ensure that o-rings are present on the cartridge and are seated into grooves; moisten o-rings with water. DO NOT use
any petroleum products to lubricate the o-rings.
3. Align tabs of new filter cartridge with existing filter head and insert new filter cartridge into head. Turn car-
tridge to the right (clockwise) until cartridge stops.
4. Open the inlet shut-off valve and flush new cartridge for four (4) gallons (approximately 5 minutes).
Water Leaks at Push-In Connections:
Push tubing in as far as it will go. If leaking continues, shut off water at the original valve and remove water line by push-
ing in on the connector collar while pulling the tubing away. Inspect tubing for cracks and scratches. If tubing is cracked
or scratched, simply cut that portion away and reinsert tubing into push-in fitting.
Make sure tubing is cut straight. If not, recut.
If water leaks, please verify that the o-ring is properly seated in its groove.
Water Does Not Flow From The Drinking Water System Faucet:
Check to see if the main water line valve is open, allowing water to flow to the filter.
Water Appears Cloudy or Air Comes Out of the Drinking Water System Faucet:
Flush the filter for four (4) gallons (approx. 5 minutes) to remove any trapped air.
DRILLING HOLE THROUGH
CAUTION
CAUTION

TROUBLESHOOTING GUIDE

6
Tabla de contenido
loading

Tabla de contenido