Poulibloc 3000; Installation Recommendations; Identifi Cation; Mounting - Nidec LEROY-SOMER POULIBLOC 2000 Instalación

Reductor de montaje pendular
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

2 - POULIBLOC 3000

2.1 - Installation recommendations

Installation must be performed by qualifi ed personnel.
Allow suffi cient room around the gearbox for plugs
accessibility.
Gearbox:
For the installation of Poulibloc 3000, follow the "Recom-
mendations" chapter in the general manual.
2.1.1 - Identifi cation
Gearbox nameplate:
1 - gearbox type ;
2 - operating position ;
3 - fi xing type (NU) ;
4 - reduction ;
5- serial number ;
6 - lubricant : Pb is lubricated with grease for 10 000 hours
running.
4
1
5
Pb 3105 B3 NU
389 417 900 / 003
N
5,08
i
min
EP 0
Pbh delivered without oil.
4
1
5
Pbh 3208 B3 NU
389 417 901 / 001
N
7,85
i
min

2.1.2 - Mounting

Mount the unit directly on the driven shaft of the machine,
then secure it axially by tightening two pointed grub screws
provided, (Pbh series) or by one screw and washer at the end
of the shaft.
In order to make easier the mounting and later a possible
removal, it is strongly recommended to coat the driven shaft
and the hollow shaft with molybdenum disulfur grease.
Only parallel keys.

2.2 - Lubrication

Pb 3000 :
For operation between -20°C and + 40°C, the gearbox Pb 3000
is normally supplied lubricated for 10 000 hours running with
grease.
Pbh 3000 :
Gearbox Pbh 3000 is supplied without oil. Before running it
is necessary to:
1 - install drain plug (magnetic) to lowest gearbox point ;
2 - fi ll up approximatly to one third of the height (considering B3
position) ;
3 - place the breather plug to the highest gearbox point.
Recommended oil: for operation between -10 and +50°C,
mineral oil extreme pressure EP ISO VG 220 ; between
-30 and +50°C: synthetic oil PAO ISO VG 150.
18
INSTALLATION - POULIBLOC 3000
2 3
-1
6
2 3
-1
6
For very low speed applications the gearbox must be
completely fi lled since ther is no splash lubrication.
Running in: change oil after approximately 200 hours.

2.2.1 - Plugs position

1
2
3
4

2.2.2 - Oil quantity

1
Place the breather plug at the top of the gearbox
Operating
Plugs
position
type
B3
3
4
3
1
4
B6
4
3
3
2
B7
3
4
3
B8
3
1
4
4
1
V5
2
1
1
1. Tolerance: ± 0.05 litre for oil quantity < 5 litre
Level
- Draining
- Breather

2.3 - Maintenance

The gearboxes do require a minimum of care, and, when
dismantled following instructions:
- mineral oil: drain every 5 000 hours.
- synthetic oil: for operating temperature < or = 70°C, drain
every 25 000 hours. It is nevertheless recommended to check
proper oil level periodically.
It is important to check periodically that the belt tensions are
not excessive and that the alignement of the drive is correct.
Observe the lubricant instruction.
Consult us for details regarding abnormal temperature
conditions and suitable oils.
An excess of oil may cause overheating and
leakage.
Installation guide - POULIBLOC 2000-3000
2
Pbh 31
Pbh 32
Pbh 33
G 1/2"
G 1/2"
G 1/2"
litre
1
litre
1
litre
1
1
1.7
2.75
1
1.7
2.75
1
1.7
2.75
1
1.7
2.75
1
1.7
2.75
- Filling
3097 en - 2019.02 / g
Tabla de contenido
loading

Este manual también es adecuado para:

Leroy-somer poulibloc 3000