Name
Code-No.:
Design:
Material:
Power:
Temperature range:
Coolant:
Capacity:
Dimensions:
Weight:
Accessories:
We reserve the right to make technical changes!
5. Installation and operation
5.1 Positioning and connection
CAUTION!
The installation and connection of the device should be made only by
qualified specialist establishment.
Positioning
Unpack the device and remove any packing material.
Place the device on a firm, dry, level and waterproof surface adapted to the impact of
high temperatures and sufficient load-bearing capacity for the weight of the device
including the entire contents.
Never place the device on flammable surfaces.
Saladette 900T2 +GL
200275
for 3x 1/6 GN and 2 x 1/1 GN,
GN containers 150 mm deep ***
2 doors
circulating air cooling
housing: chrome-nickel steel; cutting board: polyethylene
0.187 kW / 230 V 50 Hz
0 °C – 10 °C
R134a / 200 g
250 litres
W 900 x D 700 x H 850 mm
57.0 kg
2 grid – shelves 1/1 GN, stainless steel;
2 adaptor bar: length 326 mm, width 25 mm;
2 adaptor bars: length 535 mm, width 35 mm;
4 adaptor bars: length 174 mm, width 25 mm
electronic control
condensation water evaporation
with foamed evaporator
***
Delivery without GN containers!
- 43 -