4. Switch the control panel back to user
mode, press:
engineer
installer code
5. Perform another operating test (see §
Operating test).
It is essential to replace the lithium battery
with the same type of battery
(3.6 V BatLi05).
Please dispose of the old battery
in a battery recycling bin.
9.3 Maintenance
Check and clean the product regularly.
Any form of dirt or substance that may be
deposited on the surface of the lens can limit
or modify the detection performance.
Example:
• the presence of frost on the lens may even
make the detector inoperative,
• a detector with a lens fouled by plant
deposits or pollution may cause a false
or delayed activation.
Specifications
Detection
Coverage
Use
Power supply
Battery life
Li
Radio links
Fixing methods
Operating temperature
Degrees of mechanical protection
Anti-tamper protection
Dimensions L x W x H
Weight
outdoor motion detector 2 x 12 m
infrared
2 x 2 to 12 m adjustable beam assemblies
inside/outside
3.6 V - 4 Ah BatLi05 lithium battery
5 years in normal conditions of use
(110 detections max./day)
TwinBand
: 433/434 MHz, 10 mW max
®
869 MHz,
wall
- 20°C a + 50°C
IP 55
against opening
56 x 128 x 235 mm
596 g
79
GB
S145-22X
25 mW max