7.3 Adjustment of the sensitivity
This adjustment makes it possible to adjust
the sensitivity level of the detector.
For environmental conditions:
• difficult (wind, bad weather...), decrease the
sensitivity(position L),
• standard sensitivity leave the switch in
position M.
When the detection angle has been adjusted
by 3° (see Horizontal adjustment of the
detection angle), or if maximum sensitivity is
required at the detection limit (at a distance
of around 12 m), set sensitivity to H.
7.4 Adjustment of the operational
The adjustment of the options is done by 3 DIP switches located inside the detector.
Operating options DIP switches
CAuTIon: if you position dip-switch 2
Sensitivity
selector switch
or dip-switch 3 on on, this will lower the
(L, M, H)
battery life.
ON
ON
ON
ON
ON
ON
77
Detector in TeST mode,
LED lights during each detection.
Detector in noRMAL mode,
LED remains off (except if the DIP switch
n° 3 is on ON).
The period between radio transmissions
depends on the position of DIP switch n° 2.
5 sec. battery saving timer
radio transmissions are limited to a 5
second timer interval even if multiple
detections occur.
120 sec. battery saving timer
Radio transmissions are limited to a
120 second timer interval even if multiple
detections occur.
Position recommended in the event
of frequent passage inside the zone
of detection.
Selecting LeD indicator status
The LEDs light up on detection
in both test and normal operating mode.
Selecting LeD indicator status
The LEDs light up on detection
in test mode only.
Position recommended in the event
of frequent passage inside the zone
of detection.
GB