Replacing Burner tube
1) Your Weber
Q
grill must be OFF and cool.
®
2) Unscrew and remove propane cylinder from the valve/regulator assembly.
3) Open the lid.
4) Remove cooking grate.
5) Unscrew and remove the 1/4 x 20 inch stainless steel hex nut and stainless
steel washer that holds the burner tube inside the cook box(a).
6) Carefully slide the burner tube out from the cook box.
m Caution: The burner opening(1) must be positioned properly
over the valve orifices(2).
7) To reinstall the burner, reverse 5) through 7).
Make sure the igniter port hole (a) lines up with the arrow tab (B) on the
igniter box.

ignition System operations

If the ignition system fails to ignite the burner, light the burner with a match. If
the burner lights with a match, then check the ignition system.
Check that both the white(1) and black(2) ignition wires are attached
properly.
Check that the ignition button pushes the igniter (button) down, and returns
to the up position.
If the ignition system still fails to light, Contact the Customer Service
Representative in your area using the contact information on our web site.