G
B
Should the drive arm be replaced, use a M14X20 or longer
as extractor of the arm from the PREMIER 24V shaft. Just
screw it in.
A
DJUSTMENT OF THE MECHANICAL STOPPERS
Adjust the mechanical stoppers as shown in Pic. 8.
When the gate is completely closed, slide the close mechanical stopper (F)
against the arm. Then tighten it (key n. 5) with the two Allen screws 6x20
provided. In case an electric lock is fitted on the gate, the close mechanical
stopper must be removed.
To adjust opening position, slide the open mechanical stopper (G) against
the arm (gate must be opened completely) and tighten it as described
above.
Caution: Always use two Allen screws for every stopper.
Caution: The drive arm is equipped with an anti-theft locking device (E in
Pic. 5). If the close mechanical stopper is not properly adjusted
the anti-theft device can get damaged in a short period.
M
AINTENANCE
Maintenance should be carried out by skilled and qualified staff only, after
switching off the mains supply.
Regularly lubricate the hinges of the gate every 6 months and keep the force
monitored (according to EN12453).
G
30
30
7
F
8