is probably lower than acceptable (the
battery has been in deep discharge
for too long). In this case, keep the
battery in the charger for a long time
(up to several hours), then remove and
re-insert it. If the indicator then starts
blinking green, the battery is good but
if it keeps lighting up red it's defective.
Do not use the battery!
INSTALLATION
Remove the protective cover from the
Battery Pack.
Lift the lever (12).
Insert the battery into the dedicated
slot in the device body until it stops so
that element F (see Fig. 2 on the flyleaf) is located below.
Lock the battery by lowering the lever.
PRECAUTIONS
Only use the charger supplied with the Battery Pack. The use of any other charger may irreparably damage
the Battery Pack or the charger and may cause fire.
During long-term storage, the Battery Pack should be partially charged – the charge level should be between
50% and 80%.
Do not charge the Battery Pack immediately after bringing it from a cold environment to a warm one. Wait for
30-40 minutes for the Battery Pack to get warm.
Do not leave the Battery Pack unattended while charging.
Never use a modified or damaged charger.
Charge the Battery Pack at a temperature from 0 °C to +45 °C, otherwise the battery life will decrease
significantly.
Do not leave the Battery Pack with a charger connected to the mains after charging is complete.
Do not expose the Battery Pack to high temperatures or a naked flame.
Do not submerge the Battery Pack in water.
Do not connect an external device with a current consumption that exceeds permitted levels.
The Battery Pack is short circuit protected. However, any situation that may cause short-circuiting should be
avoided.
Do not dismantle or deform the Battery Pack.
When using the Battery Pack at sub-zero temperatures the battery capacity decreases. This is normal and is
not a defect.
Do not use the Battery Pack at temperatures above those shown in the table – this may decrease battery life.
Do not drop or hit the Battery Pack.
Keep the Battery Pack out of the reach of children.
EXTERNAL POWER SUPPLY
The thermal imaging scope can be powered with an external power supply such as Power Bank (5 V).
Connect the external power supply to the USB port (4) of the device.
The device will switch to operation from the external power supply and the IPS7 Battery Pack will begin slowly
charging.
The display will show the battery icon
THERMAL IMAGING SCOPE HELION 2 XQ
C
D
E
Mains Adapter
Charger
Battery Pack
with the charge level as a percentage.
If the device operates on external power supply but the IPS7 Battery Pack is not installed, the icon
shown.
When external power supply is disconnected, the device will switch to the internal IPS7 Battery Pack without
powering off.
Warning! Charging IPS7 / IPS14 Battery Packs from a Power Bank at air temperatures below 0 °C may reduce
battery life. When using external power, connect the Power Bank to the device after it has been turned on and
working for several minutes.
110-240V
OPERATION
socket
WARNING! Do not point the objective lens of the device at intensive sources of light such as devices emitting
laser radiation or the sun. This may render the electronic components inoperative. The warranty does not cover
damage caused by improper operation.
POWERING ON AND IMAGE SETUP
Open the lens cover (1).
Turn the device on with a short press of the ON (11) button.
To obtain a crisp image of the icons on the display, rotate the diopter adjustment ring (6). After this, there is
no need to rotate the diopter adjustment ring for distance or any other conditions.
To focus on an object being observed, rotate the lens focus ring (2).
To set up display brightness and contrast and smooth digital zoom, please refer to the QUICK MENU
FUNCTIONS section.
After use, turn off the device with a long press of the ON (11) button.
MICROBOLOMETER CALIBRATION
Calibration allows levelling of the microbolometer background temperature and eliminates image flaws (such
as vertical stripes, frozen images, etc.).
There are three calibration modes: Manual (M), Semi-Automatic (SA) and Automatic (A).
Select the desired mode in the menu option CALIBRATION
M Mode (Manual). Close the lens cover then press the ON (11) button briefly. Having finished calibration, open
the lens cover.
SA Mode (Semi-Automatic). Calibration is activated with a short press of the ON (11) button. You do not have to
close the lens cover (the sensor is closed with an internal shutter automatically).
A Mode (Automatic). The device calibrates by itself according to the software algorithm. You do not have to
close the lens cover (the sensor is closed with an internal shutter automatically). User assisted calibration with
the ON (11) button is also allowed in this mode (as in the Semi-Automatic mode).
DISCRETE DIGITAL ZOOM
The device allows you to quickly increase base magnification (please refer to the Magnification line in the
Technical Specifications Table) by two times or four times, as well as to return to the base magnification. To
operate the discrete digital zoom, press successively the DOWN (8) button.
QUICK MENU FUNCTIONS
The quick menu allows you to change the base settings (display brightness and contrast) and use the smooth
digital zoom and stadiametric rangefinder.
Enter the menu with a short press of the M (9) button.
To toggle between the functions below, press successively the M (9) button.
is
.
5