Hydraulic Circuit; Priming And Adjustment Of Oil Pump - Ecoflam MAX P 35 AB Manual De Instrucciones

Ocultar thumbs Ver también para MAX P 35 AB:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
420010334402 Max P 35 / 45 AB
EN
1
1
2
1 - HOSE
2 - OIL FILTER
3 - OIL COCK
4 - SUCTION
5 - RETURN
SUNTEC AS 67 B
4
5
V
SUNTEC
SUNTEC
3
2
Before starting the burner, bleed the air in the pump through the gauge port. Fill the piping with light-oil to facilitate
the pump priming. Start the burner and check the pump feeding pressure. In case the pump priming does not take
place during the first prepurging, with a consequent, subsequent lock-out of the burner, rearm the burner's lock-out to
restart, by pushing the button on the control box. If, after a successful pump priming, the burner locks-out after the
prepurging, due to a fuel pressure drop in the pump, rearm the burner's lock-out to restart the burner. Do never allow
the pump working without oil for more than three minutes. Note: before starting the burner, check that the return
pipe is open. An eventual obstruction could damage the pump sealing device.

HYDRAULIC CIRCUIT

3

PRIMING AND ADJUSTMENT OF OIL PUMP

1 - INLET
2 - RETURN
3 - BLEED AND PRESSURE GAUGE PORT
4 - VACUUM GAUGE PORT
5 - PRESSURE ADJUSTMENT
3
6 - TO NOZZLE
6
P
VERIFY:
- That piping system is perfectly sealed.
- That the use of hoses is avoided whenever is possible (use copper pipes
preferably).
3
- That depression is not greater than 0,45 bar, to avoid pump's cavitation.
- That check valve is suitably designed for the duty.
1
The pump pressure is set at a value of 12 bar during the testing of burners.
V1
4
5
V2
14