To reduce
the chance
of FLASHBACK
FIRE you must
clean
the Burner
Tubes
as follows
at least once
a month
in summer
and fall or whenever
spiders
are active
in your
area, and if your grill has not been
used for an extended
period
of time.
1.
Turn
all Burner
Valves
to the full OFF
position.
2.
Turn the LP Gas tank valve to the full OFF
position.
3.
Detach
the LP Gas regulator
assembly
from
your
gas
grill.
4.
Remove
the Cooking
Grids
and Heat Diffuser from
your
grill.
5.
Remove
the screws
from the rear of each
Main
Burner
using
a Phillips
Head
Screwdriver.
Remove
screws
along
all sides
of the Infra-red
Burner
using
a Phillips
Head
Screwdriver.
6.
Carefully
lift each
Burner
up and away from
the Gas Valve
Orifice.
7.
Check
and clean
burner/venturi
tubes
for
insects
and insect
nests. A clogged
tube
can lead to a fire beneath
the grill.
8.
Refer to Figure
1 and perform
one of these three
cleaning
methods:
[]
METHOD
1: Bend
a stiff wire
or wire
coat
hanger
into
a small
hook
as
shown
and
run the
hook
through
the
Burner
Tube
and
inside
the
Burner
several
times
to
remove
debris.
,)
[]
METHOD
2: Use
a bottle
brush
with
a
flexible
handle
and
run
the
brush
through
the
Burner
Tube
and
inside
the
Burner
several
times
to
remove
any
debris.
[]
METHOD
3: Use
an
air hose
to force
air
through
each
Burner
Tube.
The
forced
air
should
pass
debris
or
obstructions
through
the
Burner
and
out the
Ports.
Figure
1
TO CLEAN BURNER TUBE,
INSERT HOOK AS INDICATED BY THE ARROW
Regardless
of which
Burner
cleaning
procedure
you
use, we recommend
you also complete
the following
steps to help prolong
Burner
life.
1. After each
use of the main
grill or infrared
cooking
zone
it is necessary
to burn off food
particles
and
drippings
which
can clog Burner
ports
and reduce
Burner
performance.
OPEN
the grill Lid, ignite the
burner(s)
and operate
grill on Hi setting
for
3 to 5 minutes.
You can close the Lid if only main
Burners
are lit, but NEVER
close
the Lid over
a lit
Infrared
Burner.
2. Use a nylon brush,
blower
or vacuum
to remove
accumulated
ash from the outer surface
of each
Burner.
Clogged
tube
style Burner
ports
can be
cleaned
with a stiff wire, such as an open
paper
clip.
DO NOT use a stiff brush
or sharp
tool of any type on
the fragile
infrared
Burner.
3. Inspect
each
Burner
for damage
(cracks
or
holes)
and if such
damage
is found,
order
and
install a new Burner.
After
installation,
check
to ensure
that the Gas Valve
Orifices
are
correctly
placed
inside
the ends of the Burner
Tubes.
Also check
the position
of your
Spark
Electrode.
For
safe
operation
ensure
the
Gas
Valve
Assembly
Orifice
is inside
the
Burner
Tube
before
using
your
grill.
See
figure.
If the
Orifice
is not
inside
the
Burner
Tube,
lighting
the
Burner
may
cause
explosion
and/or
fire
result-
ing
in serious
bodily
injury
and/or
property
damage.
Tube Burner
Gas Valve Assembly
Orifice
BurnerTube
Burner Tube
Griddle
Burner
......................
,
/
/
Gas Valve Assembly
/
/
_
Burner
Port
Foot
u_uu
u uuuuu
uuu
uuuuu
u u u_u
u u u uu
u u u u_u
u u uuu
uu
uuu
u uu_:_:_
\
/
_
Burner Tube
27