Electrical ShockHazard
- Plug intoa grounded 3 prong outlet.
- Donotremove ground prong.
- Donotuseanadapter.
- Donotuseanextension c ord.
Failure t o follow these instructions canresult i ndeath,
fire,orelectrical shock.
Theappliance c omes witha 3-wire power supply cord,
ULlisted intheUSA.
Theappliance r equires a 3-wire receptacle.
Thereceptacle mustbeinstalled b ya licensed e lectrician
only.
Thesocket m ustbefused witha 10to 16Afuse.Please
observe i nthiscoherence thefollowing t able:
Appliance
MAXloadatonetime
Refrigerator 24"
2.0Ampere
Refrigerator 30"
2.0Ampere
Freezer 18"(incl. I ceMaker)
3.5Ampere
Freezer 24"(incl. I ceMaker)
4.0Ampere
Freezer 30"(incl. I ceMaker)
4.5Ampere
Wineunit18"
2.0Ampere
Wineunit24"
2.0Ampere
Orient ground prong tothebottom asshown inthepictures.
Fortheinstallation position ofthereceptacle see"Installation
dimensions", page 9.
Additional
grounding
procedure
Some local regulations may require a seperate ground.
In such cases, the required accesseory ground wire, clamp
and screw must be purchased seperately.
Never ground the appliance to plastic plumbing lines,
gas lines or water pipes.
Grounding
instruction
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for the
electric current
Improper connection of the equipment grounding con-
ductor may result in electric shock. Have the appliance
checked by a qualified electrician or service technician
if you are in doubt as to whether the appliance has
been properly grounded.
Only connect the appliance to drinking water!
A cold water connection is required for operation of the
automatic ice maker. The water pressure must be between
25 and 120 p.s.i. (1.72-8.25 bar). The installation must
comply with local plumbing regulations.
A separate shut-off valve must be installed for the appliance
water connection.
The shut-off valve for the water connection must not be
behind the appliance. It is recommended to place the shut-
off valve directly next to the appliance (base unit) or in
another easily accessible location.
When installing the water connection, observe the permitted
installation areas for the pipe. For the permitted installation
areas and dimensions see "installation dimensions", page 9.
The supply pipe can be located at the side on the right (a), at
the side on the left (b) or underneath (c).
Maximum outer diameter of the water pipe
(without fittings):
13/32" (10
mm).
Attach a separate shut-off valve for the water connection
in a suitable, easily accessible location.
Do not use a self-piercing valve!