5. Button bar
5.1.7
Viewing on-board help for the active screen
1. Press the
button.
2. Press the
button.
5.1.8
Status displays
Important tool status information is displayed in the top right-hand corner of the screen.
Status indicator → page 25
Status indicator
5.1.9

Further information

POS 150 (http://qr.hilti.com/r51292)
POS 180 (http://qr.hilti.com/r51294)
6

Calibration and adjustment

6.1
Calibration review
The tool is correctly adjusted when supplied. The values to which the tool is set may change over time or
due to temperature fluctuations, transport or aging. The tool therefore incorporates a feature that allows the
settings to be checked and, if necessary, corrected by carrying out in-the-field re-calibration. This is done
by setting up the tool securely on a tripod of good quality and targeting an easily visible, clearly discernible
prism within ±3 degrees of horizontal at a distance of approx. 50 - 70 m.
After this, follow the instructions on the display.
Tool parameters that are checked by in-the-field calibration and electronically adjusted:
2035736
*2035736*
Printed: 08.05.2018 | Doc-Nr: PUB / 5153826 / 000 / 04
Compensator on / off
EDM
Active target
Type
Setting including status laser pointer and the laser plummet
Battery state of charge: 0 - 100%
English
25