Internal Battery Replacement
SU3000XLCD Model
1a
Remove the screw from the left of the front bezel.
1b
Remove the front bezel.
2
Remove the screws that hold the metal battery compartment
panel in place (in front of the battery compartment on the
bottom). Remove the metal panel from the UPS.
3
Remove the batteries using the pull tab, and disconnect the
DC connectors from the UPS.
Note: Please memorize the original battery position and orientation to ensure
that you install the new batteries correctly.
4
Insert the new battery set into the UPS in the same position as
the original set.
5
Reconnect the DC connector (red-to-red, black-to-black).
6
Replace the metal battery compartment panel. Reinstall the
screws that hold the metal bar in place.
7
Reinstall the front bezel and replace the screw on the left of
the bezel to secure it to the cabinet.
13-03-138 93-3168-EN.indd 29
1a
1b
2
3
29
3/28/2013 1:06:07 PM