Campbell Hausfeld VX4002 Manual De Instrucciones Y Lista De Piezas página 15

Compresores horizontales de aire portatiles de 15, 20 y 30 galones
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING GUIDE (CONTINUED)
SYMPTOM
Motor hums and runs slowly or
not at all (Continued)
Reset mechanism cuts out
repeatedly or circuit breaker
trips repeatedly
Tank does not hold pressure
when compressor is off and
the shut off valve is closed
Pressure switch continuously
blows air out the unloader
valve
Excessive vibration
Pressure switch does not
release air when the unit shuts
off
POSSIBLE CAUSE(S)
7. Defective unloader valve on pressure
switch
8. Defective motor capacitor(s)
9. Defective motor
1. Lack of proper
ventilation / room temperature too
high
2. Too many devices on same circuit
3. Restricted air intake
4. Loose electrical connection
5. Pressure switch shut-off pressure set
too high
6. Malfunctioning check valve
7. Defective unloader valve on pressure
switch
8. Defective motor capacitor(s)
9. Malfunctioning motor
1. Air leaks (fittings, tubing on
compressor, or plumbing outside
system)
2. Worn check valve
3. Check tank for cracks or pin holes
Malfunctioning check valve
1. Loose fasteners on pump or motor
2. Belt needs replaced
3. Belt alignment
Malfunctioning unloader valve on
pressure switch
CORRECTIVE ACTION
7. Replace unloader valve.
8. Replace capacitor(s).
9. Replace motor.
1. Move compressor to well-ventilated area.
2. Limit the circuit to the use of only the air
compressor.
3. Clean or replace filter element.
4. Check all electrical connections.
5. Replace pressure switch.
6. Replace check valve.
air pressure in tank.
7. Replace unloader valve.
8.Replace capacitor(s).
9. Replace motor.
1. Check all connections with soap and water solution.
Tighten; or remove and apply sealant to threads,
then reassemble.
2. Replace check valve.
Risk of Explosion. Do not disassemble check valve with
air pressure in tank.
3. Replace tank. Never repair a damaged tank.
Replace the check valve if the unloader valve on the
pressure switch bleeds off constantly when unit shuts
off.
air pressure in tank.
1. Tighten fasteners.
2. Replace with correct size.
3. Align flywheel and pulley.
Replace the unloader valve if it does not release the
pressure for a short period of time when the unit shuts
off.
with air pressure in tank.
13
Risk of Explosion. Do not
disassemble check valve with
Risk of Explosion. Do not
disassemble check valve with
Risk of Explosion. Do not
disassemble unloader valve
Tabla de contenido
loading

Este manual también es adecuado para:

Vx4011Vt6290Vt6182Vt6183Vt6104Vt6271

Tabla de contenido