PREX H 3 COND
MODEL: PREX H 3 COND 65 (OIL)
Trademark: LAMBORGHINI CALORECLIMA
Condensing boiler: YES
Low-temperature boiler (**): NO
B1 Boiler: YES
Combination heater: NO
Cogeneration space heater: NO
Item
Seasonal space heating energy efficiency class (from A++ to G)
Rated heat output
Seasonal space heating energy efficiency
Useful heat out put
Useful heat output at rated heat output and high-temperature regime (*)
Useful heat output at 30% of rated heat output and low-temperature regime (**)
Useful efficiency
Useful efficiency at rated heat output and high-temperature regime (*)
Useful efficiency at 30% of rated heat output and low-temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In standby mode
Other items
Standby heat loss
Ignition burner power consumption
Annual energy consumption
Sound power level
Emissions of nitrogen oxides
(*) High-temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return temperature (at heater inlet).
MODEL: PREX H 3 COND 65 (GAS)
Trademark: LAMBORGHINI CALORECLIMA
Condensing boiler: YES
Low-temperature boiler (**): NO
B1 Boiler: YES
Combination heater: NO
Cogeneration space heater: NO
Item
Seasonal space heating energy efficiency class (from A++ to G)
Rated heat output
Seasonal space heating energy efficiency
Useful heat out put
Useful heat output at rated heat output and high-temperature regime (*)
Useful heat output at 30% of rated heat output and low-temperature regime (**)
Useful efficiency
Useful efficiency at rated heat output and high-temperature regime (*)
Useful efficiency at 30% of rated heat output and low-temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In standby mode
Other items
Standby heat loss
Ignition burner power consumption
Annual energy consumption
Sound power level
Emissions of nitrogen oxides
(*) High-temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return temperature (at heater inlet).
ErP product fiche
ErP product fiche
cod. 30902840 - Rev. 00 - 02/2018
Symbol
Unit
Value
A
Pn
kW
60
η
%
92
s
P4
kW
59,5
P1
kW
19,1
η
%
90,9
4
η
%
97,9
1
elmax
kW
0,170
elmin
kW
0,170
PSB
kW
0,003
Pstby
kW
0,450
Pign
kW
0,000
QHE
GJ
187
LWA
dB
65
NOx
mg/kWh
111
Symbol
Unit
Value
A
Pn
kW
60
η
%
91
s
P4
kW
59,5
P1
kW
19,7
η
%
87,4
4
η
%
96,8
1
elmax
kW
0,174
elmin
kW
0,150
PSB
kW
0,003
Pstby
kW
0,450
Pign
kW
0,000
QHE
GJ
189
LWA
dB
65
NOx
mg/kWh
74
EN