Customized Cycle Mode

In Customized Cycle Mode, you set the amount of time the fan is On (Run Period) or Off (Idle Period).
Each period can be set between 10 minutes and 120 minutes in increments of 5 minutes. The controller
will cycle between the two periods. For example, if you set the Run Period to 10 minutes and the Idle
Period to 20 minutes, you have established a cycle of 30 minutes. During every cycle, the fan will turn On
for 10 minutes and Off for 20 minutes.
The Run Period and Idle Period
are available only if the controller
is in Customized Cycle Mode
(see opposite page). To set the
periods, press the main button for
3 seconds to display the setup
menu and proceed as shown:
Press the main button for 3 seconds at any time (or do not press any button for 60 seconds) to save any
changes you have made and exit the setup menu.