Remington I-LIGHT PRO FACE&BODY Guía De Uso Y Cuidado página 8

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 78
ENGLISH
F WARNING: always clean the Flash Window before use with the lint-free cloth provided to ensure there
is no oil or debris on the lens.
, Skin Contact Sensor (fig. 1- 13&20)
The Skin Contact Sensor is a safety mechanism that prevents the device from accidental activation. In order
for the device to activate, the Skin Contact Sensor must be fully depressed against the skin.
, Flash Button (fig. 1-5)
The Flash Button is located on the hand piece. To activate the flash bulb, ensure the Skin Contact Sensor is
fully engaged and press the Flash Button.
, Bulb Status Indicator Display (fig. 1-8)
The device is ready to flash when the Bulb Status Indicator Display is illuminated green.
NOTE: if the Flash Button is pressed AND the Skin Contact Sensor is not fully engaged OR the Bulb Status
Indicator Display is not illuminated, an audible "beep" will sound. When the Bulb Status Indicator Display
illuminates yellow, there are 150 flashes remaining in the flash bulb. When the Bulb Status Indicator Display
flashes yellow, the bulb cartridge has been used up and will no longer operate. You must replace the bulb
cartridge to continue using the device.
, Treatment Head Release Buttons (fig. 1-14)
Press both buttons and gently pull to remove the treatment head.
F WARNING: ALWAYS ensure the unit is OFF and the power cord is disconnected before removing the nose
cone. If the nose cone is removed while the unit is powered ON, all indicator lights on the base unit will flash
and audible "beeps" will sound.
GETTING ACQUAINTED WITH i-LIGHT
C
, Long-Life Light Cartridge (fig. 1-15)
The long-life light cartridge will deliver 65,000 flashes regardless of the energy level selected. While it is
unlikely you will ever need to replace it; it can be replaced by another long-life cartridge or SP-6000SB which
delivers 1,500 flashes per cartridge. Please contact your local Remington® Service Centre.
, Energy Level Selection (fig. 1-6)
The i-Light device is equipped with 5 energy levels. Level 1 is the lowest setting and level 5 is the highest
setting.
TIP: For the most effective results, always use the highest energy level that does not cause discomfort on the
skin. To determine the energy level being used, observe the number of lights illuminated on the Energy
Level Display (fig 1 - 9).
Your i-Light device will automatically be set to Energy Level 1 each time the device is powered ON. To
change the level, press the Energy Level Selection Button.
, Test the i-Light device on your skin
1. Review the Warnings and Safety Precautions.
2. Familiarise yourself with the features of the i-Light.
3. Consult the Skin Tone Chart to ensure your skin colour is in the acceptable range (fig. 5).
8
Tabla de contenido
loading

Tabla de contenido