2-2. CONVERGENCE
Before starting convergence adjustments:
1
Perform FOCUS adjustments.
2.
Set Picture mode to "CUSTOM".
3.
Feed in dot pattern.
Vertical Static Convergence
1.
Adjust the 4 pole magnet to converge red, green and blue dots in
the center of the screen.
Center dot
R
G
B
2.
Tilt the 4 pole magnet and adjust static convergence to open or
close the 4 pole magnet.
3.
When the 4 pole magnet is moved in the direction of arrow
B
, the red, green, and blue dots move as shown below:
A
B
B
Moved RV750 (H.STAT)
R
G
B
KV-29FA350/29FA750
R
G
B
4 pole magnet
RV750
H. STAT
RV1800
G2 (SCREEN)
A
B
B
B
G
G
R
R
R
G
B
Horizontal Static Convergence
If the blue dot does not converge with the red and green dots, use the 6
pole magnet to adjust as shown:
R G
R
DY pocket
4 Pole
Magnet
Y Separation Axix Correction Magnet
A
and
Adjustment
1.
Input cross hatch pattern.
2.
Set Picture to "MINIMUM", Brightness to 'STANDARD".
3.
Adjust the Y separation axis correction magnet on the Neck
Assembly so that the horizontal lines at the top and bottom of the
screen are straight.
B
R
G
B
R
B
R
G
B
G
G
R
6 Pole
Magnet
6 Pole Magnet
Purity
4 pole Magnet
Blue
Red
KV-29FA350/29FA750
G B
B
Blue
Red
14