Facom V.DA100KR Instrucciones Originales página 7

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
• Hold the tool with a light but safe grip, talking account of the required hand-
reaction forces, because the risk from vibration is generally greater when the grip
force is higher.
• Air under pressure can cause severe injury.
• Never direct air at yourself or anyone else.
• Cold air shall be directed away from the hands.
USING THE MACHINE
• Before using the machine, check that there is no dangerous interaction with the
immediate environment (explosive gas, inflammable or dangerous liquid, unknown
piping, electric sheathing or cable, etc).
• Before connecting the machine to the air inlet, check the trigger is not blocked in the
on position by an obstacle and no adjustment or assembly tool is still in position.
• Check the machine is connected to the network by a quick disconnect joint and
that an air braker valve is close by to shut the air down immediately in the event of
blockage, breakage or any other incident.
• Keep hands, loose clothing and long hair away from rotating end of machine.
• Locate center of new hole by using a center punch. Place drill bit tip in punch mark.
Hold drill square with work and start motor. Apply steady, even pressure. Do not force.
Too much pressure can cause bit to break or over heat. Too little pressure will keep bit
from cutting and cause it to over heat.
• Reduce pressure just before bitcuts through the work. When bit has penetrated work
and is spinning freely, take it from the work while the motor is running, then turn off
drill.
• If the drill jams in the work, release throttle immediately. Disconnect the drill before
removing bit and determining cause or trouble.
MAINTENANCE
Your FACOM drill has been designed to operate over a long period of time
with a minimum of maintenance. Continuous satisfactory operation depends
upon proper tool care and regular cleaning.
Lubrication
Every eight hours' operation, if a lubricator is not used on the compressed
air network, inject 1/2 to 1cm
through the machine's inlet connection.
3
Do not use damaged, frayed or deteriorated air hoses and fittings.
Air powered machine can vibrate in use. Vibration, repetitive
motions or uncomfortable positions may be harmful to your hands
and arms. Stop using any machine if discomfort, tingling feeling
or pain occurs.
Seek medical advice before resuming use.
Do not carry the machine by the hose.
Keep body stance balanced and firm. Do not overreach
when operating this machine.
Do not use the machine under the influence of drugs, alcohol,
medication or if you are tired.
NU-V.DA100KR_0616 ok bis.indd 7
• Whenever universal twist couplings (claw couplings) are used, lock pins shall be
installed and whipcheck safety cables shall be used to safeguard against possible
hose-to-tool and hose-to-hose connection failure.
• Keep the drills and tappers sale by regular preventative maintenance.
• Check the speed and make a simple check of the vibration level after each service.
• Check the speed regularly.
Do not attempt to free the bit by strating and stopping the motor.
• Anticipate and be alert for sudden changes in motion during start up and
operation of any power machine.
• Ensure that the unit on which the work is being carried out is immobilised.
• In the event of blockage, release the trigger and disconnect the machine
from the compressed air network.
• Use accessories recommended by FACOM.
• The use of other than genuine FACOM replacement parts may result in safety
hazards, decreased machine performance, and increased maintenance, and cancel
all warranties.
Repairs should be made only by authorized trained personnel. Consult your
nearest FACOM Authorized Servicenter.
If the air supply, hoses and connectors are in order, and the tool is still not
functionning properly, disconnect tool from hose, disassemble tool, replace worn
or damaged parts, clean, reassemble, and relubricate; or take tool to your nearest
authorized FACOM service center.
Cleaning
WARNING: Never use solvents or other harsh chemicals for cleaning the
non-metallic parts of the tool. These chemicals may weaken the plastic
materials used in these parts. Use a cloth dampened only with water and
mild soap. Never let any liquid get inside the tool; never
immerse any part of the tool into a liquid.
WARNING
Use protective equipment such as glasses, gloves, safety shoes as
well as acoustic protection.
Remain vigilant, use common sense and pay attention when using
the machine.
Always turn off the air supply and disconnect the air
supply hose before installing, removing or adjusting
any accessory on this machine, or before performing any
maintenance on this machine.
When working with certain materials, exposure to dust may be
dangerous for health.
Get information on the composition of the material you are
working on and use suitable protective equipment. If in doubt, use
as much protection as possible.
18/07/2016 14:42:39