Before laying the lining
Check that the vertical movement of the door is work-
ing correctly
Do not install or leave inflammable material inside the
lining. Before starting to install the lining, make sure
no inflammable material is present in the area that
will be covered by the lining itself.
Loading firewood
Pull-up the door using the vertical opening handle and
lift (FIG.1). Use a thermal glove to carry out this oper-
ation. After loading the necessary firewood, close the
door completely; do not operate the fireplace while
the door is open to avoid damaging the door seals.
Cleaning glass elements
At the end of every lighting cycle, and depending on
the quality of the firewood used and on the draw of
the flue, it may be necessary to clean the unburned
dust present on the glass.
Never clean the glass during fireplace operation, al-
ways wait until it has completely cooled down.
To open the door horizontally, pull up the horizontal
opening handle (FIG.1). Perform the glass cleaning
process using a suitable detergent.
Cleaning of painted surfaces
Never clean the fireplace while the fireplace is in op-
eration, always wait until it has completely cooled
down. To clean painted surfaces use a smooth cloth
slightly dampened with water.
Cleaning the ash pan
The ash pan is located under the grill inside the com-
bustion chamber. Before removing the ash pan make
sure that the fireplace has completely cooled down.
Never remove the ash pan while the fireplace is lit. To
remove the ash pan lift the grid at the centre of the
combustion chamber with the tool provided. Residues
from the combustion process can be very hot for a
long time after the fireplace was used, therefore only
use a metal container to empty the ashes.
ECK model specifications
Fumes outlet diameter: 250 mm
Minimum length of Flue: 5 meters
Rated power:13 kW
Performance: 75%
Fumes outlet average temperature at the pipe fitting:
298°C