Kenmore 51672 Guía Para El Uso Y Cuidado página 20

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Water
Filter
Data
System
Specification
and Performance
Data Sheet
®
Refrigerator
Water
Filter
Cartridge
Model
9005
Specifications
Service
Flow
Rate (Maximum)
.............................................
075 GPM (283 L/min)
Rated
Service
Life Model
9005
(Maximum)
.........................
500 gallons/
1892 liters
Maximum
Operating
Temperature
........................................
100 ° F/38 ° C
Minimum
Pressure
Requirement
..........................................
35 psi/ 138 kPa
Maximum
Operating
Pressure
..............................................
120 psi/827
kPa
]
General
Use Conditions:
Read this Performance
Data Sheet and compare the capabilities of this unit with your actual
water treatment needs.
DO NOT use this product where water is microbiologically
unsafe or of unknown
quality without adequate disinfection
before or after the system. System certified for cyst reduction may be used on disinfected water that may contain
filterable
cysts.
The retractable water filtration system uses a 9005 replacement cartridge (see Sears contact information
at the front of your
manual to order). Timely replacement
of filter cartridge is essential for performance
satisfaction from this filtration system.
Please refer to the applicable section in this Use and Care Guide for general operation,
maintenance
requirements and
troubleshooting.
This system has been tested according to ANSI/NSF 42 and 53 for reduction of the substances
listed
below. The concentration
of the indicated substances
in water entering the system was reduced to a
concentration
less than or equal to the permissible limit for water leaving the system, as specified in
ANSl/NSF 42 and 53.
Performance
Data*
Substance
Lead
Lead
Cyst
Turbidity
Lindane
Atrazine
Chlorine
Particulate**
2,4-D
Asbestos
Influent
Water
0.15 mg/L
O.15 mg/L
25000 count/mL
11.8 NTU
0.00063 mg/L
0.0097 mg/L
1,9 mg/L
286667 count/mL
291.6667 ug/L
458 MFL/mL
Effluent
Average
0.001 mg/L
0.002 mg/L
lcount/mL
0,12 NTU
0.00005 mg/L
0.0002 mg/L
0,09 mg/L
900 count/mL
45.45 ug/L
0,16 MFL/mL
Average
%
Reduction
99.33%
96.66%
99.99%
98,98%
92.06%
97.93%
95.26%
99.68%
84.42%
99.96%
Maximum
Effluent
0.001 mg/L
0.003 mg/L
3 count/mL
0,18 NTU
0.00005 mg/L
0.0006 mg/L
0,17 mg/L
2400 count/mL
1OOug/L
0,16 MFL/mL
Min. Required
Inlet
Reduction
pH
0.010 mg/L
6,5
0.010 mg/L
8.5
> 99.95%
NA
0.5 NTU
NA
0.00001 mg/L
NA
0.003 mg/L
NA
->75%
NA
->85%
NA
0.0017 mg/L
NA
99%
NA
."
Tested using a flow rate of 0.75 GPM (2.83 L/min,) and a maximum pressure of 120 psi (827 kPa)
under standard laboratory conditions; however, actual performance may vary. Health Claim
Performance tested and certified by NSF International.
Particle size range classification
of test. Particles used were 0.5 -1 microns.
Cafifomia Certificate number01-1486