Placing Tool In Service - Ingersoll Rand 293 Manual De Instrucciones

Ocultar thumbs Ver también para 293:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY.
WARNING
Always wear eye protection
when operating or perform-
ing maintenance on this tool.
WARNING
Air powered tools can vibrate
in use. Vibration, repetitive
motions or uncomfortable po-
sitions may be harmful to your
hands and arms. Stop using
any tool if discomfort, tingling
feeling or pain occurs. Seek
medical advice before resum-
ing use.
WARNING
Keep body stance balanced
and firm. Do not overreach
when operating this tool.
SETTING THE POWER REGULATOR
Impact wrenches are not torque control devices.
Fasteners with specific torque requirements must be
checked with suitable torque measuring devices after
installation with an impact wrench.
Models 293/293S–EU Impactools are equipped with a
combination power regulator/reverse valve designed to
provide power adjustment while maintaining full power in the
reverse direction. Since the reverse direction is used primarily
for loosening right–hand threaded fasteners and full power is
required, no provision is make for power adjustment in this
direction. The power output is calibrated by the numbers "1"
through "5" stamped on the Housing Cover Assembly.
LUBRICATION
Ingersoll–Rand No. 50
Always use of an air line lubricator with these tools.
We recommend the following Filter–Lubricator–Regulator
Unit:
For International– No. FRL30–C6–A29
For U.S.A. – No. C31–06–G00
After each two or three hours of operation, unless an air
line lubricator is used, inject 3 cc of Ingersoll–Rand
No. 50 Oil into the Inlet Bushing (2).
After each twenty hours of operation, inject about 6 cc
of Ingersoll–Rand No. 100 Grease into the Grease
Fitting (33).
Model
Type of
Handle
293, 293–EU
pistol
293S, 293S–EU
pistol
H
Tested in accordance with ANSI S5.1–1971 at free speed
♦ Tested to ISO8662–1 loaded with frictionbrake to 9 RPM
ISO3744
WARNING LABEL IDENTIFICATION
Always wear hearing
protection when operating
this tool.
Do not carry the tool by the
hose.
90 psig
Operate at 90 psig (6.2 bar/
(6.2bar/620 kPa)
620 kPa) Maximum air pres-
sure.
ADJUSTMENTS

PLACING TOOL IN SERVICE

SPECIFICATIONS
Drive
Impacts
per min.
in.
1
810
#5 spline
810
WARNING
WARNING
WARNING
The numbers 1 thru 5 on the housing are only for
reference and DO NOT denote a specific power output.
One (1) designates the lowest power while five (5) denotes
the highest.
Power Adjustment in the Forward Direction
1. While facing the back of the Impactool, push the
Reverse Lever to the extreme right position.
2. Using a screwdriver, rotate the Power Regulator so
that the slot aligns with the desired power calibration.
3. The power of the tool is now adjusted for the forward
direction but will still have full power in the reverse
direction. This adjustment will not change regardless of
how many times you shift the Reverse Lever as long as
you do not change the power selection.
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
HSound Level
Recommended
Torque Range
ft–lbs (Nm)
Pressure
1000–1600
90.3
(1356–2169)
1000–1600
90.3
(1356–2169)
2
WARNING
Always turn off the air sup-
ply and disconnect the air
supply hose before install-
ing, removing or adjusting
any accessory on this tool,
or before performing any
maintenance on this tool.
WARNING
Do not use damaged, frayed
or deteriorated air hoses
and fittings.
International Warning Label:
Order Part No. ___________
FILTER
COMPRESSOR
(Dwg. TPD905–1)
♦Vibrations
dB (A)
Level
•Power
m/s
103.3
12.1
103.3
12.1
2
Tabla de contenido
loading

Este manual también es adecuado para:

293s293–eu293s–eu

Tabla de contenido