Alternator With Double Bearing - B35T; Bearing Replacement; Maintenance Of The Exciter; Exciter - WEG AG10 Serie Manual De Instalación, Operación Y Mantenimiento

Alternadores sincrónicos
Ocultar thumbs Ver también para AG10 Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

www.weg.net

6.5.5.2 Alternator with double bearing - B35T

To perform the exchange of the bearings in the alternator
with double bearing, it is necessary to disassemble the
alternator entirely, according to the procedure described
on item 6.10.

6.5.5.3 Bearing replacement

The bearing disassembly should always be made using
the appropriate tools (bearing puller).
Figure 6.2: Device to withdraw bearings
ATTENTION
A bearing should only be removed from the
shaft when absolutely necessary.
Instructions:
1. The extractor grabs must be applied on the side of the
bearing inner ring to be disassembled or on an
adjacent part;
2. Before installation of new bearings, the shaft seats
should be cleaned and lightly lubricated;
3. The bearings must be heated to a temperature
between 50 °C and 100 °C to facilitate assembly;
4. The bearings should not be subjected to shock, drops,
and storage with vibration or humidity, which can
cause marks on the internal races or in the balls,
reducing their life.

6.6 MAINTENANCE OF THE EXCITER

6.6.1

Exciter

For the proper performance of its components, the exciter
alternator should be kept clean.
Check the insulation resistance of the windings of the
exciter main and of the auxiliary exciter (if any) periodically
to determine the insulation condition of the same by
following the procedures described herein.
6.6.2

Test on the diodes

Diodes are components that have great durability and do
not require frequent tests. If the alternator indicating a
defect presents failure in the diode or an increase in field
current for the same load condition, then the diodes
should be tested in accordance with the following
procedure:
1. Release the connections of all the diodes with the rotor
winding of the exciter;
2. With an ohmmeter, measure the resistance of each
diode in both directions.
40 l Installation, operation and maintenance manual – Synchronous Alternator – AG10 line - Horizontal
NOTE
When testing diodes, observe the polarity
of the test terminals concerning polarity of
the diode.
An arrow on its frame indicates the polarity
of the diode.
The current conduction must occur
only in the anode-cathode direction,
i.e. in the condition of direct
polarization.
The diode is considered good when presenting low
ohmic resistance (up to approximately 100 Ω) in its
forward direction and high resistance (approx. 1 MΩ) in
opposite direction. Defective diodes have ohmic
resistance 0 Ω or greater than 1 MΩ action in both
measured directions.
In most cases, the method with ohmmeter to test the
diodes is sufficient to identify faults in the diodes.
However, in some extreme cases it may be necessary to
apply the rated voltage of blocking and / or current flow
for detecting fault in the diodes. Due to the efforts required
for these tests, in case of doubt, it is recommended to
perform the exchange of the diodes.
6.6.3

Replacement of the diodes

To access the diodes and perform the exchange, it is
necessary to remove the exciter cover:
To replace the diodes, proceed as follows:
Undo the connection of the 6 diodes to the exciter
rotor;
Release support for diodes and remove it;
Fix the support in a bench lathe with protection on the
jaw, and remove all diodes;
Install three new diodes of the same polarity (AND or
CTD) in one of two connection bridges;
Install the other connecting bridge, three new diodes
of polarity opposite of the three diodes previously
installed;
Fix all diodes, tightening them with a torque wrench
respecting the tightening torques in Table 6.2;
Fix the set of diodes in the alternator;
Make the connections of the diodes with the exciter
rotor winding.
ATTENTION
It is essential that the tightening torques
indicated be respected so that the diodes are
not damaged in the assembly.
Table 6.2: Tightening torque of the diodes
Diode base
Torque key of
thread (mm)
torquemeter
M6
M8
Tightening
torque (mm)
(mm)
11
2
17
3
12638144