PRE-OPERATION
BATTERY INSTALLATION:
. Attach terminals to a lead-acid battery already charged.
Mount the battery onto the position as specified below, with
its terminals facing inward.
2. Insert each long bolt through the specified hole, its tip pointing
outward.
3. Put the supporting arm on the long bolts and tighten with
the butterfly nuts. (Push the lead-acid battery all the way
inward.)
4. Arrange the wiring so that it won't be damaged by possible
vibration caused by the engine.
5. Only after checking that the engine's starter key in the "OFF"
position, securely connect the red cable, to the positive (+)
terminal. And then connect the other cable to the negative (-)
terminal.
Red Cable: to the (+) terminal
Black Cable: to the (-) terminal
CAUTION:
ENGINE DAMAGE WILL OCCUR IF THE TERMINAL CONNECTIONS
ARE CONNECTED IN THE INCORRECT MANNER.
1
Battery Base
2
Flange Bolt
3
Screw
4
Battery Band
5
Bolt and Nut
6 Battery cover
5
LESS THAN
131 mm [5.2 in.] (AC-G3200i)
162 mm [6.4 in.] (AC-G4300i)
LESS THAN
114 mm [4.5 in.] (AC-G3200i)
136 mm [5.4 in.] (AC-G4300i)
RED CABLE
24
Preparing the Generator
Accessory parts
RED
CABLE
(GEN-3200)
(GEN-4300)
(GEN-3200)
(GEN-4300)
Part
Number
4
6
1
3
2
LESS THAN
(GEN-3200)
71 mm [2.8 in.] (AC-G3200i)
(GEN-4300)
82 mm [3.2 in.] (AC-G4300i)
RECOMMENDED BATTERY
LEAD-ACID BATTERY
GEN-3200-iMS0 GEN-4300-iMS0
YTX7L-BS
YB2AL-A
or equivalent
or equivalent
Operator's Manual