Connecting
Electrical
Loads
Let engine stabilize and warm up for a few minutes after
starting.
o Plug in and turn on the desired J2OVokAC,
single phase,
60 Hz electrical
loads.
o DO NOT connect 240Voff
loads to the J20Vok duplex
receptacles.
o DO NOT connect 3-phase loads to the generator.
o DO NOT connect 50 Hz loads to the generator.
o DO NOT
OVERLOAD
THE
GENERATOR°
See
"Don't
Overload
Generator".
See"Don't
Overload
Generator"°
Start generator
and let engine stabilize before connecting
electrical
loads.
Connect
electrical
loads in OFF position, then turn ON for
operation.
Turn electrical
loads OFF and disconnect
from generator
before stopping generator.
Stopping
the
Engine
I.
Turn OFF and unplug all electrical loads from generator
panel receptacles. NEVER start or stop enghe with
electrical devices plugged in and turned ON.
2.
Let engine run at no°load for several minutes to
stabilize internal temperatures
of engine and generator.
3.
Move on/off switch to "Off"
position.
CAUTION
DO NOT stop engine by moving choke [ever to "Choke"
position.
4.
Move
fuel valve to "Off"
position.
NEVER attempt
to power a device requiring
more amperage
than generator
or receptacle can supply.
DO NOT overload the generator,
See "Don't
Overload
Generator",
[ 20 Volt AC, 20 Amp,
Duple×
Receptacles
Each duplex
receptacle
(Figure 7) is protected
against
overload
by a push-to-reset
circuit breaker.
Use each receptacle
to operate
120Volt AC, single-phase,
60 Hz electrical
loads requiring
up to 2,400 watts
(2.4 k_¢)
at 20Amps
of current.
Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater).