Appendix 1 - Technical Specifications - WEG CVW300G2 Guia De Instalacion

Para tracción eléctrica
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Variable Speed Drive for Electric Traction
Seq.
Action/Result
- Monitoring mode.
1
- Press the ENTER/MENU key to get in to
the first level of the programming mode.
- The PARAM group is selected, press the
2
or
keys to select the STARTUP
group.
- Press ENTER/MENU when the group is
3
selected.
- T he pa ra mete r " P 0 317 – O r i e n t e d
Star tup" is then selected, press the
4
ENTER/MENU to get into the parameter
content.
- Change the parameter P0317 to "1 – Yes",
5
using the
key.
- When the desired value is reached press
6
ENTER/MENU to save.
- In this mom e nt the O r ie nte d S ta r t-
uproutine is initiated and the "CONF"
status is indicated at the keypad (HMI).
- The parameter "P0000 – Access to
7
Parameters" is selected. Change the
password to set the remaining parameters
if necessary.
- Press the
key to the next parameter.
- If necessary, change "P0296 – Battery
Rated Voltage". This change will affect
8
P0151, P0185, and P0400.
- Press the
key to the next parameter.
- Set parameter "P0202 – Typeof Control"
pressing "ENTER/MENU". Press the
key to select the desired option: "[1] =
Sensorless" or "[2] = Encoder". This
modification resets the content of P0410.
Then, press "ENTER/MENU". There are
9
three options to exit the oriented start-up:
1 - Running the Self-tunning.
2 - Manual settings of parameters from
P0409 to P0413.
3 - Changing P0202 from vector to scalar.
- Press the
key to the next parameter.
- If necessary, change "P0398 – Motor
Service Factor" parameter. This change
10
will affect the current and the time of the
motor overload protection operation.
- Press the
key to the next parameter.
- If necessary, change "P0400 – Motor
Rated Voltage" parameter. This change
11
corrects the output voltage by the factor
"x = P0400/ P0296".
- Press the
key to the next parameter.
12 | CVW300G2
Display Indication
Seq.
- If necessary, change "P0401 – Motor
12
- Press the
- If necessary, change "P0404 – Motor
13
- Press the
- If necessary, change "P0403 – Motor
14
- Press the
- If necessary, change "P0402 – Motor
15
- Press the
- If necessary, change "P0405 – Encoder
16
- Press the
- In this moment the keypad presents
17
- Pre s s BAC K / E S C key to f inis h the
18
- Press BACK/ESC key again to get back
APPENDIX 1 – TECHNICAL SPECIFICATIONS
Table A.12: Technical specifications of CVW300G2 model
Action/Result
Rated Current" " parameter. This change
will affect P0156, P0157, P0158 and P0410.
key to the next parameter.
Rated Power" parameter. This change
will affect P0410.
key to the next parameter.
Rated Frequency " parameter. This
change will affect P0402.
key to the next parameter.
Rated Speed". This change will affect
P0122 to P0131, P0135, P0182, P0208,
P0288 and P0289.
key to the next parameter.
Pu l s e s N u m b e r " ac cording to the
encoder model.
key to the next parameter.
the option to perform "Self-tunning".
The Self-tunning should be performed
whenever it is possible. Press "ENTER/
MENU" key to access parameter P0408
and press
to select the desired
option. Then, press "ENTER/MENU"
to start the Self-tunning. The keypad
will show "CONF" and "RUN"status
simultaneously during the self-tunning.
At the end of the self-tuning, the "RUN"
status is automatically erased and the
content of P0408 automatically goes
back to the.
start-up routine.
to the monitoring mode.
Figure 11: Start-up Oriented to the vector mode
Model
CVW300A0400D0NB66G2
Input rated voltage
Input voltage limits
40 °C
Output rated current
50 °C
Peak output current
Output voltage
Rated
Dissipated power
Peak
Weight
Environment temperature
-25...50°C (-13...122°F)
Display Indication
24...48 V
18...66 V
200 A
200 A
400 A
Vcc
2
300 W
910 W
5,9 kg