Electrical Data - Urmet 1039/82 Manual De Instrucciones

Cabezal de lectura para sistema ipervoice/interfaz para lector rf
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

FEATURES AND INSTALLATION
The reading head is used to operate an electrical lock when:
A Urmet Ref. 1101/50 proximity key is approached to the frontal part.
The hall opening button (PA) is pressed.
The two-color led changes color (from red to green) to indicate recognition of a proximity key moved close
to the front panel. The LED lights up green when operating the lock.
The device may be powered by the PoE switch 1039/44 or /45 or by an external power supply unit.
Follow the indications below during installation:
Connect the Ethernet PoE RJ45 port to the PoE switch with the cable 1039/90 (connect terminals V+ /V-
to the external power supply unit if the port to which the device connected is not of PoE type).
Connect the PA terminals to the external lock button.
Connect SP terminals to the open door sensor (optional).
Connect the relay output to a lock.
§
To install a tamper (normally closed), cut the wire and make the connection as shown below.
Refer to the system manual for more information on how to use the device in Ipervoice systems.

ELECTRICAL DATA

External power supply unit data (+V, -V)
Consumption:
Voltage:
Working temperature range:
Max. relay contact power:
Maximum switching voltage:
Maximum switching current:
Maximum switching load:
Max. distance from hall button:
Max. distance from open door sensor:
Max. distance from supplementary
power supply unit (+V; -V):
DS1039-046A
V+
LAN
V-
PA
SP
NC
C
NO
25m with cable cross-section area 0.5mm
50m with cable cross-section area 1.5mm
100m with cable cross-section area 1.5mm
ENGLISH
TAMPER
100mA max. @48V
44 – 56Vdc
-20°C to +80°C
40VA 25W
30V
3.5A
2
2
2
3
Tabla de contenido
loading

Este manual también es adecuado para:

1039/83

Tabla de contenido