P2530-H
see front page) and in combination with our accessor-
ies, to which this declaration relates is in conformity
with the appropriate standard(s):
EN 792-4
and in accordance with the following directive(s):
2006/42/EC
Technical file available from:
Quality Manager, Atlas Copco Tools, Stockholm,
Sweden
Stockholm, 29 December 2009
Lennart Remnebäck, General Manager
Signature of issuer
Installation
Air quality
• For optimum performance and maximum machine
life we recommend the use of compressed air with
a maximum dew point of +10°C. We also recom-
mend the installation of an Atlas Copco refrigera-
tion-type air dryer.
• Use a separate air filter of type Atlas Copco FIL.
This filter removes solid particles larger than 15
microns and also removes more than 90 % of li-
quid water. The filter must be installed as close
as possible to the machine/equipment and prior
to any other air preparation unit such as REG or
DIM (please see Air Line Accessories in our main
catalogue). Blow out the hose before connecting.
Models which need air lubrication:
• The compressed air must contain a small quantity
of oil.
We strongly recommend that you install an Atlas
Copco oil-fog lubricator (DIM). This should be
set according to air consumption by the air line
tool according to the following formula:
L = Air consumption (litre/s).
(May be found in our sales literature).
D = Number of drops per min (1 drop = 15 mm
L* 0.2 = D
this applies to the use of long work cycle air line
tools. A single point lubricator type Atlas Copco
Dosol can also be used for tools with short running
cycles.
Information about Dosol settings may be found
under Air Line Accessories in our main catalogue.
EN
Lubrication-free models:
• In the case of lubrication-free tools it is up to the
customer to decide on the peripheral equipment
to be used. However, it is no disadvantage if the
compressed air contains a small quantity of oil
e.g. supplied from a fog lubricator (DIM) or Dosol
system. This does not apply to turbine tools, which
should be kept oil free.
Compressed air connection
• The machine is designed for a working pressure
of 6–7 bar = 600–700 kPa = 87–102 psi.
• Blow out the hose before connecting.
Maintenance
Maintenance
Lubricate the machine regularly with air tool oil.
If the machine is used every day, it should be
overhauled and cleaned once every six months.
The use of other than genuine Atlas Copco replace-
ment parts may result in decreased tool performance
and increased maintenance and may, at the option
of the company, invalidate all warranties.
Cleaning
At 100 hour operating intervals or earlier if operation
becomes sluggish or the machine shows sign of
sticking, flush through with paraffin or a similar
material. Immediately after flushing thoroughly oil
the machine with air tool oil.
Grease guide
Brand
BP
Esso
Q8
Mobil
Shell
Texaco
Molycote
3
)
Useful information
You can find all kind of information concerning Pro
products, accessories, spare parts, published matters
on our WEB site!
C Log in to www.atlascopco.com/pro
© Atlas Copco Tools - 9836 3984 00
Safety and operating instructions
Grease
Energrease LS-EP2
Beacon EP2
Rembrandt EP2
Mobilegrease XHP 222
Alvania EP2
Multifak EP2
BR2 Plus
Air lubrication
Energol E46
Arox EP46
Chopin 46
Almo Oil 525
Torcula 32
Aries 32
5