8 Troubleshooting
The motor doesn't work:
Verify:
• The wiring of the motor.
• The power supply specifications.
• The compatibility of the control
• The heat generated (wait for the cooling of the motor).
The equipment stops too soon:
Verifiy:
• The operation of end-limits during the rotation of the motor.
• The crown is properly fitted to the tube.
• The end-limits of the motor are properly adjusted.
• That the shade is within the recommended weight limit.
The equipment is noisy:
Verify that:
• The wheel and the crown are well adapted to the used tube.
• The mechanical plays between motor, accessories, tube and end of tube must be de-
creased to the maximum.
• The wheel is properly fixed to the tube.
• The equipment is not constrained between the brackets.
• The length of the notch is adapted to the motor hook or to the used crown.
• Debris, screws or other are not in your tube.
• The power supply specifications.
• The temperature of the environment is in conformity with the operating temperature.
14
Copyright © 2011 Somfy SAS. All rights reserved - V0 - 06/2011