Display
Function
L2
Loop 2
Activating this parameter, any loop that is
connected to the Loop 2 input will serve as a
SAFETY/CLOSE function.
Y
Loop 2 enabled
no
Loop 2 disabled
(see note regarding Loop 1)
S 1
Loop 1 sensitivity
Adjusts the sensitivity of the vehicle detection
loop
00
Minimum sensitivity
1 0
Maximum sensitivity
S2
Loop 2 sensitivity
Adjusts the sensitivity of the vehicle detection
loop
00
Minimum sensitivity
1 0
Maximum sensitivity
Mt
Motor movement
Using the function provided by this para-
meter makes it possible to manually move
the barrier bar, operating as dead-man.
Pressing + will open the automated system,
pressing - causes the automated system to
close.
oP
pressing +, open
cL
pressing -, close
St
AUTOMATED SYSTEM STATUS:
This allows you to choose whether to quit the programme
and save the data.
Y
= quit and save the data
no
= quit without saving the data
On quitting the programme, press the F key to display
the status of the automated system
00
Beam closed
0 1
Beam open
02
Stationary ready to open
03
Stationary ready to close
04
Automated system paused
05
Opening
06
Closing
07
Failsafe in progress
08
2-EASY device verification in progress
09
Pre-flashing then OPENS
10
Pre-flashing then CLOSES
1 1
EMERGENCY Open
You can go to St at any time by simultaneously
pressing F and -.
Default
Displaying of the automated system status
important for the installing/maintenance technician in order
to distinguish the logical processes that the board carries
no
out during movement.
If, for example, the automated system status is CLOSED,
the display MUST read
received, the display will change to
enabled, or directly to
0 1
display
05
Example of a status sequence displayed starting from a closed barrier
05
--
00
Beam closed
0 1
Beam open /
04
Pause
The sequence does not include statuses
correspond to pre-flashing when opening and closing,
respectively.
5.2 Changing the predefined parameters set
The E680 board features six sets of pre-defined configurations that
allow rapid adapting to the size of the beam installed, making it the
starting point for a fine adjustment of the parameters. To select one
of the available configurations, you must change the parameter
dF
from the pre-set value
corresponding to the barrier configuration (beam length, type and
number of accessories installed) shown in Tables 4 or 5 on page
24 (e.g. choose default
with foot and lights).
To complete configuration, it is necessary to exit the Basic
Configuration menu by pressing "F" until parameter
or by pressing "F" and "-"
10
St
00
. When the OPEN command is
09
, if pre-flashing is
05
(the OPENING movement) to then
once the position of gate OPEN is reached).
05
Opening
06
Closing
09
and
00
(neutral condition) to the value
04
for a beam measuring 5 m in length
St
is extremely
10
which
is reached
Tabla de contenido