Partial update: only parts of the system software are overwritten or written.
Partial updates can be dimensioned in such a manner that the user data is
not lost. Partial updates are particularly suitable for subsequently installing
applications or for updating.
The procedure is the same in all cases, the different effects result from the
datasets used.
The following is required in order to carry out the software installation:
-
Commercially available FAT32 formatted USB memory stick with minimum
512 MB free memory.
-
Mini USB adapter cable (included in scope of delivery)
-
Update / recovery-dataset (.zip archive, is offered int he download area for
the product)
-
Archiving software (e.g., Windows Explorer , 7zip or similar)
In order to install a system software, we recommend the following procedure.
z Download the dataset (.zip archive) from the download area for the product
z Unzip the update / recovery dataset into the root directory of the USB stick
z If a device is mounted flush with the wall, press left and right evenly
against the housing until the locking mechanism is audibly released.
The device is guided out of the wall. The operating elements on the upper
edge are accessible.
z Connect the enclosed adapter cable USB/mini USB to the socket (4) if
necessary.
z Connect the USB stick with the touch panel or adapter cable.
z Restart the Android touch panel by pressing the reset button or by discon-
necting from the power supply,
Now the update / recovery is started automatically when starting up the
device.
z Follow the instructions on the screen in order to conclude the procedure.