10.2 Self test
The best fault trace software on the market has also been de-
veloped with this machine. In this mode all the important input
and outputs to and from the computer can be tested. Some
outputs controls heating lamps, cooling fans, laser etc and will
give the opportunity to quick and accurate function control of
the different parts in the machine.
10.2.1 Push button test
All buttons on the control unit are tested. The
corresponding symbols are displayed in the display win-
dow by pressing the appropriate buttons. Press "Enter"
for approx. 3 seconds in order to
continue the automatic testing programme.
10.2.2 Display test
Verify that all pixels light up on the display. Press Enter
and check that all pixels go out.
10.2.3 Buzzer test
Check that the buzzer sounds.
10.2.4 Cassette IR test
The IR cassette lamps light up. Check that all the IR
lamps are lit. This test is limited to 10 seconds.
10.2.5 Ventilator test / cassette
The ventilator in the cassette should now start. Sound
from the ventilator confirms that it is working.
Attention: If the mobile dryer is equipped with 2 cassettes, the
Sections 10.2.4 and 10.2.5 are repeated for the other cassette.
10.2.6 Laser test
Direct the laser towards the object at a distance of
0.3 - 1 m. Check that a red circle is visible on the
object.
10.2.7 Temperature sensor test
Direct the temperature sensor towards an object that
is at room temperature. The temperature on the
display should not deviate from room temperature
by more than ±3°C/±5°F.
12
Trisk CureMaster 2 DTL
10.2.8 Distance sensor test
Direct the distance sensor towards the object at
a distance of 0.3 -1 m. Check that the distance
shown on the display matches the measured dis-
tance. A deviation of ±3 cm is acceptable.
10.2.9 Temperature guards
The computer card has a temperature measuring
device that is displayed in this window .
The temperature is shown in ºC or ºF depending
on the settings you have made.
Automatic testing is now complete.
# 420878 Rev 1
11. Programming example
11.1
PREHEATING / EVAPORATION
Initial temperature
20°C
Time
4 min
Temperature increase
15°C / min
Final temperature
80°C
11.2
PREHEATING / EVAPORATION
Initial temperature
20°C
Time
4 min
Temperature increase
20°C / min
Final temperature
60°C
DRYING
Initial temperature
60°C
Time
5 min
Temperature increase
5°C / min
Final temperature
60°C
11.3
PREHEATING / EVAPORATION
Initial temperature
20°C
Time
4 min
Temperature increase
10°C / min
Final temperature
60°C
DRYING
Initial temperature
60°C
Time
8 min
Temperature increase 20°C / min
Final temperature
110 °C
11.4
PREHEATING / EVAPORATION
Initial temperature
20°C
Time
6 min
Temperature increase 20°C / min
Final temperature
60°C
DRYING
Initial temperature
60°C
Time
6 min
Temperature increase 15°C / min
Final temperature
90 °C
# 420878 Rev 1
Trisk CureMaster 2 DTL
13