Réglage De La Température Limite - Kohler K-11748-K Guía De Instalación Y Cuidado

Ocultar thumbs Ver también para K-11748-K:
Tabla de contenido
Temperature Limiting Adjustment
Black Tab
Setscrew
Patte noire
Vis de retenue
Lengüeta negra
Tornillo de fijación
Valve Stem
Tige de valve
Espiga de la válvula
CAUTION: Risk of personal injury. If the water temperature is set too high,
scalding will occur. The water temperature should never be set above 120°F
(49°C).
Turn the valve stem clockwise to the full open position. Allow the water to run for
several minutes.
Using a thermometer, check the water temperature.
Turn off the water.
Minor Temperature Adjustments
Using a hex wrench, turn the setscrew clockwise to lower the temperature and
counterclockwise to raise the temperature.
Recheck the water temperature.
Major Temperature Adjustments
Remove the O-ring and collar from the valve stem.
Turn the valve stem clockwise in small increments. Check the water temperature
at each increment.
Once the desired maximum water temperature is reached, leave the water running
and reinstall the collar to the valve stem with the setscrew positioned against the
black tab.
Turn off the water.
Reinstall the O-ring.
Réglage de la température limite
ATTENTION: Risque de blessures. Des brûlures peuvent se produire si la
température de l'eau est trop élevée. La température de l'eau ne doit jamais être
réglée à une température supérieure à 120°F (49°C).
Tourner la tige de la vanne dans le sens des aiguilles d'une montre en position
entièrement ouverte. Laisser l'eau couler pendant plusieurs minutes.
1128093-2-D
Collar
Collier
Collarín
Minor Adjustment
Major Adjustment
Réglage mineur
Réglage majeur
Ajuste menor
Ajuste mayor
24
O-Ring
Joint torique
Arosello
Kohler Co.
Tabla de contenido
loading

Este manual también es adecuado para:

K-11748-ks

Tabla de contenido