0.3%, 2.5% & 5%
Models
RINSE INJECTOR AFTER EACH USE
Additive allowed to remain in injector can dry, foul or
damage the lower end at the next start-up. Place suction
tube into a 1 qt. (0.95 liters) or more container of fresh
filtered water. Flow fresh water through the injector by
operating until container is empty. This procedure is not
needed for continuous operation.
CLEAN SOLUTION CONTAINER
Keep covered to prevent dirt, debris from entering the
container. Rinse container thoroughly and often. Do not
mix chemicals together that might react and cause a
precipitate. Use FILTERED fluid when filling container.
CLEAN SUCTION TUBE FILTER SCREEN
Inspect each time new solution is added. Clean filter
screen (#27) and suction tube (#25) as necessary by
rinsing in fresh water. Replace if necessary. Keep filter
screen off bottom of solution container to prevent dirt
and precipitate from clogging filter.
CLEAN INLET FILTER
Clean or replace inlet filter as required to increase the life
of the unit as well as reduce pressure loss.
BYPASS INJECTOR
When not in use place the injector in bypass mode by
using the three valve bypass.
STORAGE
For extended storage, rinse injector (see "Rinse Injector
After Each Use") and place underwater in a container.
Apply monthly, <0.1 oz. (29 ml) of chlorine bleach to
avoid algae growth. KEEP FROM FREEZING.
English: 10
Remote Injecting
Fig. 5
Remote Injector
Kit shown on a
single injector.
10% Models
Maintenance
Reference numbers refer to Pages 14 - 20
Remote Injector Kit
(not included)
Is recommended for the following:
Single Injector:
To prevent mineral buildup within the body of the unit.
Use when injecting chemicals that cause minerals to
precipitate from fluid (see Fig. 5)
NOTE: when mixing more than one chemical, always refer
to your chemical manufacturer information guide for
proper application. Contact your local distributor or Hydro
Systems customer service for information or to order.
Perform these maintenance
procedures to extend the life of your unit.
Refer to page 15 & 16
SuperDos 20 (0.3%) Model (Including PAA)
Every 3 - 6
Every 6 - 12
Months
months
1. Clean seal areas (#13).
1. Replace #17 O-ring
2. Check #17 O-ring,
and #51 Dosage Piston
#68 Cylinder, clean
Shaft Assembly.
and/or replace as
2. Clean and/or replace
necessary.
#13 Check Poppet, #11
Suction Tube Fitting.
Refer to page 17, 18 & 19
SuperDos 20 (2.5% & 2.5% WSP), (5%) Models
Every 3 - 6
Every 6 - 12
Months
months
1. Clean seal areas
1. Replace #17 O-ring
(#14 & #13, #44 -
and #44 Dosage Piston/
WSP).
gasket (WSP model).
2. Check #17 O-ring,
2. Clean & inspect #13
#7 Cylinder, clean
Check Poppet , #11
and/or replace as
Suction Tube Fitting.
necessary.
Refer to page 20
SuperDos 20 (10%) Models
Every 3 - 6 Months
1. Clean seal areas (#14).
1. Replace #17 O-ring
2. Check #17 O-ring, #7
and #44 Dosage Piston.
Cylinder, clean and/or
Clean and/or replace.
replace as necessary.
2. Replace #60 hose kit.
Kit Part Numbers
012705
Replace as
necessary
1. #68 Cylinder
2. #51 Shaft
Assembly
Replace as
necessary
1. #7 Cylinder
2. #14 (#44 - WSP)
O-ring
Every 6 - 12
Replace as
months
necessary
1. #7 Cylinder
2. #14 O-ring