Care and maintenance

The laser range finder requires no special care. Do not wipe off coarse dust (e.g. sand) from the
lens, but rather blow it off or remove it using a fine animal­hair brush. Fingerprints may affect
the lens surfaces after a time.
The easiest way to clean lens surfaces is to breathe on them and rub them using a clean optic­
cleaning cloth. Prevention of a fungal film on the optic, which can occur particularly in the
tropics, can be helped by storage in a dry place and good ventilation of the external lens surfaces.
Do not expose the equipment to long periods in the sun without a protective cap or bag. The
lens and the eyepiece can function like a magnifying glass and damage internal components.

Spare parts

Should you require spare parts, e.g. such as eye cups or eyepiece caps, please contact your dealer,
the representative for your country, or our customer service.
We are available for customer service enquiries by telephone from Monday to Friday between
8.00 and 18.00 CET.
Tel.: +49 (0) 64 41­ 4 67 61
Fax: +49 (0) 64 41­ 4 83 69
22

Technical specifications

Magnification
Lens diameter
Exit pupil diameter
Twilight number
Field of view at 1000 m/yd
Diopter adjustment range
Exit pupil relief
Waterproof in accord. with DIN ISO 9022­8
Function temperature
2
Dimensions (W x H x D)
Weight with battery
Measuring range
1
Measuring accuracy
Measuring duration
Laser wave length
Laser beam divergence
Battery
Battery life at + 20 °C
CE label In accordance with directive 2004/108/EC
EMC EN 55022: Class B and EN 61000­6­2
FDA Compliant with 21 CFR 1040.10 and 1040.11 except for deviations.
In pursuance of laser notice no. 50, dated 26
EN laser class 60825; 2002
Eye­safe laser class 1M in accordance with EN and FDA
The range is affected by the size and degree of reflection of the object as well as by the weather
1
and by exposure to sunlight.
2
Low temperature value is limited by battery performance. Product will also work below –
10 °C/14 °F.
Subject to changes in design and scope of delivery as a result of ongoing technical development.
ZEISS VICTORY 8x26 T* PRF
8x
26 mm
3,25 mm
14,4
110 m/yd
± 3,5 dpt
17,5 mm
Up to 100 mbar (= 1 metre)
– 10 bis + 50 °C
ca. 98 mm x 48 mm x 130 mm
Approx. 310 g
10 – 1300 Yard / 10 – 1200 metres
±1 m to 600 m / ± 0.5 % over 600 m
Maximum approx. 4 seconds
904 nm
ca. 4 x 2 mrad
1 x 3V type CR 2 lithium round cell
> 2000 measurements
July 2001
th
23