Changing Attachments; Commissioning; Working Notices; Switching On / Off - Parkside PES 200 A1 Instrucciones De Utilización Y De Seguridad

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Before taking tool into use / Commissioning
Knife / Scraper attachment (offset)
5
Knife / Scraper attachment (straight), e.g. for
6
removing carpets, felts, cork sheets as well as
plaster and adhesive residues (see Fig. C, E)
Spatula attachment (flat), e.g. for removing
7
paint residues, silicon and foams (see Fig. D)
8
Chisel attachment (flat), e.g. for carving soft
woods (see Fig. F)
Carving chisel (13 mm), e.g. for carving in
9
softwoods (see Fig. G)
©

Changing attachments

Wear suitable protective gloves when
inserting and testing attachments tool
Notice: The curve / working edge of the attachment
tool
must always point downwards.
4
Inserting a tool attachment:
Push the tool lock
Insert the attachment tool
in the tool receptor
Push the tool lock
the tool attachment is locked.
Removing a tool attachment:
Push the tool lock
Remove the inserted tool attachment
the tool receptor
3
©

Commissioning

©

Working Notices

Always work away from the body.
Hold the appliance with both hands (see Fig. B).
Introduce the attachment tool
or the area to be worked with the appliance
switched on. In that the working motion of the
appliance first takes place on contact with the
material, you will achieve a much more accu-
rate positioning of the attachment tool.
20 GB
forwards to "UNLOCK".
2
as far as it will go
4
(see Fig. A).
3
backwards to "LOCK" -
2
2
forwards to "UNLOCK".
from
4
.
4
to the material
©

Switching ON / OFF

Notice: The working motion of the appliance first
takes place on material contact.
Switching on:
Push the ON / OFF switch / Stroke rate prese-
lector
1
forwards.
Switching off:
ON / OFF switch / Stroke rate preselector
backwards.
©

Selecting the stroke rate

.
4
Note: The optimal stroke rate is dependant on
the material or the surface to be worked. It is best
determined by simple trial and error. Always start
off with the lowest setting. Should the removal be
too slight, increase the stroke rate level for level.
Slide the ON / OFF switch / Stroke rate prese-
lector
to the front to increase the stroke rate.
1
Level 1:
low stroke rate for precision work
Level 2:
moderate stroke rate
Level 3:
highest stroke rate for fast removal
Slide the ON / OFF switch / Stroke rate prese-
lector
to the rear to decrease the stroke rate.
1
©
Resharpening the
attachment tools
The best work results are only achieved with sharp
attachment tools. You should thus resharpen them
in good time.
WARNING!
the plug from the power socket before beginning
to sharpen the tools.
Place the attachment tool
into the Electric scraper (see section on
"Changing attachments").
RISK OF INJURY! Remove
to be sharpened
4
1
Tabla de contenido
loading

Tabla de contenido