AFTER EACH USE
Water should not remain in the unit for long periods of
time Sediments or minerals can deposit on pump
parts and "freeze" pump action Follow these
procedures after every use:
1
Flush chemical system by selecting system rinse
tank and run pressure washer with black low
pressure spray tip Flush for one minute or until
chemical is cleared from system.
2
Shut off engine and let it cool, then remove all
hoses.
3
Disconnect spark plug wire from spark plug
4
Empty pump of all pumped liquids by pulling recoil
handle about 6 times, This should remove most
liquid in pump.
5.
Rotate the Dial-A-Cleaner
TM
selector knob to the
OFF position.
6.
Coil high pressure hose and inspect it for damage.
Cuts in hose or fraying could result in leaks and
loss of pressure. Should any damage be found,
replace hose. DO NOT attempt to repair a
damaged hose. Replace hose with genuine
Craftsman part.
7.
Disconnect hose from spray gun and high
pressure outlet on pump. Drain water from hose,
gun, and nozzle extension and wipe off hose with
a rag.
8.
Slide one end of hose into hole on hose reel. Turn
hose reel with handle to coil hose onto reel.
9.
Reconnect spark plug wire to spark plug.
10. Store system in a clean, dry area.
,_
WARNINGt
NEVER store the engine with fuel
in the gas tank indoors or in enclosed, poorly
ventilated areas where fumes may reach an
open flame, a spark, or pilot light.
WINTER STORAGE
CAUTION
To
1.
2.
.
4.
Failure to do so will permanently damage your pump
and render your unit inoperable,
Freeze damage is not covered under warranty.
protect the unit from freezing temperatures:
Empty all chemical reservoirs as follows:
a.
Disconnect hose connected to chemical inject
fitting on pump Place end of hose into
suitable container
b.
Move selector knob to Tank A and open that
tank's cover. Gravity should shortly empty tank
contents into container.
c
When tank is empty, repeat step (b) for tanks
B and C, using different container for each
chemical
d.
Reconnect hose to chemical inject fitting on
pump Add 0.5 quart of clean fresh water to
each tank and close tank's covers
Flush chemical system by selecting a tank and run
pressure washer with with black low pressure
spray tip Flush until each tank is empty, then
switch selector knob to next tank. The last tank to
be emptied must be the System Rinse tank.
Use pump saver, available at Sears retail item
number 71-74403, to treat pump This prevents
freeze damage and lubricates pistons and seals.
If pump saver is not available, connect a 3-foot
section of garden hose to water inlet adapter Pour
RV-antifreeze
(antifreeze without alcohol) into
hose. Pull recoil handle twice. Disconnect 3-foot
hose.
16