USER'S MANUAL. MO-16X
Name
Message
*?LCK<cr>
LCK
*MIHd<cr>
MIH
*?MIH<cr>
*MILd<cr>
MIL
*?MIL<cr>
*MBWd<cr>
MBW
*?MBW<cr>
*MHId<cr>
MHI
*?MHI<cr>
*HCRd<cr>
HCR
*?HCR<cr>
*LCRd<cr>
LCR
*?LCR<cr>
*MCOd<cr>
MCO
*?MCO<cr>
*MGUd<cr>
MGU
*?MGU<cr>
*FFTd<cr>
FFT
*?FFT<cr>
*INVd<cr>
INV
*?INV<cr>
*MODd<cr>
MOD
*?MOD<cr>
04/2008
Answer
Description and Format
* LCKchhhh <cr>
Retrieve the locked status.
'c' is the lock test result: 'L for locked, 'U' for
unlocked
'hhhh' is an hexadecimal value corresponding
to a status code (see section 4.11 for error
codes)
Sets the modulator HP TS Input
'd' decimal digit
0:ASI1 1:ASI2 2:SPI or QPSK 3:TEST
Asks for the current modulator HP TS input. 'd'
*MIHd<cr>
as before
Sets the modulator LP TS input
'd' decimal digit
0:ASI1 1:ASI2 2:SPI or QPSK 3:TEST
Asks for the current modulator HP TS input. 'd'
*MILd<cr>
as before
Sets the modulator output BW
'd' decimal digit
0: 8 MHz, 1: 7 MHz, 2: 6 MHz
*MBWd<cr>
Asks for the current modulator output BW. 'd' as
before
Sets the modulator hierarchy mode.
'd' decimal digit
0: NO, 1: α=1, 2: α=2, 3: α=4
*MHId<cr>
Asks for the current hierarchy mode.'d' as
before
Sets the modulator TS high priority code rate.
'd' decimal digit
0:1/2 1:2/3, 2:3/4, 3:5/6, 4:7/8
Asks for the current CR for the high priority TS.
*HCRd<cr>
'd' as before
Sets the modulator TS low priority code rate.
'd' decimal digit
0:1/2 1:2/3, 2:3/4, 3:5/6, 4:7/8
Asks for the current CR for the low priority TS.
*LCRd<cr>
'd' as before
Sets the modulator constellation.
'd' decimal digit
0:QPSK, 1:16QAM, 2:64QAM
*MCOd<cr>
Asks for the current modulator constellation. 'd'
as before
Sets the modulator guard interval.. 'd' decimal
digit 0:1/4, 1:1/8, 2:1/16, 3:1/32.
*MGUd<cr>
Asks for the current modulator guard interval.
'd' as before
Sets the modulator FFT mode.
'd' decimal digit 0: 2K, 1: 8K
*FFTd<cr>
Asks for the current modulator FFT mode.
'd' as before
Sets the modulator spectral inversion mode.
'd' decimal digit 0:INV, 1:NO INV
*INVd<cr>
Asks for the current modulator spectral
inversion mode. 'd' as before
Sets the modulator IF output mode.
'd' decimal digit
0: COFDM, 1: TONE MAX, 2: TONE RMS
*MODd<cr>
Asks for the current modulator IF output mode.
'd' as before