Proper Use; Prior To Commissioning; Electrical Safety; Environmental Protection - Stanley SIG 2000 Silent Traducción Del Manual Original

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 78

2. Proper use

The device is suitable for applications which are
designed for operation at 230 V~ and 12 VDC. Observe
the limitations specified in the safety instructions.
The machine may only be used in accordance with its
intended purpose. Any other use is deemed improper.
In the event of damage or injuries which result from
such use, the user/operator will be liable, not the
manufacturer. Please note that our devices have not been
designed, and it is not in keeping with their proper use,
for commercial, technical or industrial use. We do not
honour the guarantee if the device is used in commercial,
technical or industrial companies or similarly.
3. Description of the device and scope of
delivery (figures 1 to 3)
1. Carrying handle
2. Tank lid with ventilation cap
3. Selection switch
4. Starter pull cord handle
5. Engine cover
6. Spark plug lid
7. Tank lid ventilation
8. Earthing connection
9. Energy saving switch
10. 1 x 230 V~ – power socket
11. 1 x 12 VDC safety trigger
12. 1 x 12 VDC connection
13. Overload indication
14. Operation indication
15. Oil warning signal
16. Oil dipstick
17. Screwdriver handle
18. Screwdriver insert
19. Spark plug socket
20. Adapter cable with 12 V power socket
21. Oil funnel
22. Spark plug
23. Spark plug socket
24. Filter element
25. Air filter lid
26. Oil filling plug

4. Prior to commissioning

Remove the packaging material and check the scope of
delivery for its completeness. Place the generator on a
stable and level surface in close proximity to the load
and in a ventilated environment.

4.1 Electrical safety:

Check electrical devices and cables. They must be in
perfect condition.
Only devices whose voltage data correspond may be
connected to the output voltage of the generator.
Never connect the generator to the power network
(power socket).
Keep the cable lengths to the load as short as possible.

4.2 Environmental protection

Dispose of dirtied maintenance materials and operating
supplies at a designated collection point.
Recycle packaging materials, metals and plastics.
4.3 Earthing
Earthing the housing is required in order to discharge
static charge. In order to do so, connect a cable on the
one side to the earthing connection of the generator (fig.
2/pos. 8) and on the other side to an external mass (e.g.
earthing rod).
4.4 Fuelling
Unscrew the tank lid (fig. 1/pos. 2) and fill a maximum of
4.0 l unleaded petrol into the tank reservoir by means of
a filler neck. Make sure not to overfill the tank resulting
in petrol spilling. Soak up spilled petrol and wait until the
petrol fumes have volatilised (risk of ignition). Lock the
tank lid.

4.5 Filling oil

Remove the engine cover (fig. 6a-6b/pos. 5) by means of
a screwdriver. Open the oil filling plug (fig. 8/pos. 26) and
9
G
B
Tabla de contenido
loading

Tabla de contenido