Promax MO-170 Manual De Instrucciones página 76

Modulador cofdm dvb-t
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Name
Message
*MREd<cr>
MRE
*?MRE<cr>
*MTSd<cr>
MTS
*?MTS<cr>
*MSSd<cr>
MSS
*?MSS<cr>
*?MPL<cr>
MPL
*MIIdddd<cr>
MII
*?MII<cr>
*MFIdddd<cr>
MFI
*?MFI<cr>
*MCBddddddd<cr>
MCB
*?MCB<cr>
*MVBdddddddddd<cr>
MVB
*?MVB<cr>
Page 28
Answer
*MREd<cr>
*MTSd<cr>
*MSSd<cr>
*MPLhhh/lll <cr> or
*MPLhhh <cr>
*MIIdddd<cr>
*MFIdddd<cr>
*MCBddddddd<cr>
*MVBdddddddddd<cr>
USER'S MANUAL. MO-170
Description and Format
PCR restamping (master mode) ON/OFF.
'd' decimal digit
0: ON 1: OFF
Asks for the current restamping state. 'd' as
before
TS lock mode MASTER or SLAVE
'd' decimal digit
0:SLAVE 1:MASTER
Asks for the current TS lock mode. 'd' as before
Active TS in SLAVE mode
'd' decimal digit
0:HP 1:LP
Asks for the Active TS in SLAVE mode. 'd' as
before
Asks for the TS packet length detected
'hhh' & 'lll' ASCII text
hhh,lll: 188 or 204 bytes for HP/LP TS (LP in
hierarchical mode only)
Initial carrier index for the blank carriers test
mode.
'dddd' decimal digits
(0000 to 6816 @ 8k, 1704 @ 2k)
Asks for the initial carrier index value. 'dddd' as
before
Final carrier index for the blank carriers test
mode.
'dddd' decimal digits
(0000 a 6816 @ 8k, 1704 @ 2k)
Asks for the final carrier index value. 'dddd' as
before
CBER value generated in test mode.
'ddddddd' decimal digits
ddddddd = CBER x 1E7
Asks for the current CBER value.
'ddddddd' as before
VBER value generated in test mode.
'dddddddddd' decimal digits
dddddddddd = VBER x 1E10
Asks for the current VBER value.
'dddddddddd' as before
12/2006